Rating Plate Information - Napoleon B46NTR Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

8
2.4

RATiNG PLATE iNfORMATiON

1
EN
DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN
ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED
MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US
STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
D
uSE wITH BARRIER w565-0228. FoLLow THE INSTALLATIoN INSTRuCTIoNS LoCATED IN THE
INSTALLATIoN MANuAL.
A
NoT FoR uSE wITH SoLID FuEL.
CERTIFIED wITH THIS uNIT oNLY.
C
wARNING:
THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE
ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES,
OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. MINIMUM CLEARANCE
TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS
FLOOR / PLANCHER
SIDES / COTES
BACK / ARRIERE
MANTEL / MANTEAU
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION
MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR DES
EXTENSIONS PLUS GRANDES.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS
D'EVACUATION MINIMALE ET MAXIMALE.
woLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
B
MATERIAL: .010 VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTER
MIN. LETTERING FOR "NoT FoR uSE wITH SoLID FuEL. ", "uN CoMBuSTIBLE SoLIDE NE DoIT pAS ETRE uTILISE AvEC CELuI. " TO BE 10 POINT ARIAL, BOLD FACE,
iNSTALLER: it is your responsibility to check off the appropriate box on the rating plate according to
UPPER CASE AND 2 POINT LEADING SPACING OR EQUIVALENT. HOLE TO BE 0.250" Ø.
BLACK ON WHITE BACKGROUND
the model, venting and gas type of the appliance.
MAX OVERALL DECAL SIZE: 4.75" x 8.50"
HOLE IS 0.250" Ø / 0.312 "FROM BOTTOM AND LEFT EDGE"
For rating plate location, see "INSTALLATION OVERVIEW" section.
SERIAL NUMBERS TO BE ASCENDING FROM B46TR 007160
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
A
This drawing is the property of Wolf Steel LTD. or NAC.
It is not to be reproduced nor used in any manner
NOTE: The rating plate must remain with the appliance at all times. it must not be removed.
without our consent. All rights are reserved.
A barrier designed to reduce the risk of burns from the hot viewing glass, it is provided with the
1
appliance and shall be installed.
W415-1613 / B / 06.13.16
2
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
9700539 (WSL)
4001658 (NAC)
B46NTR
B46NTRE
0-4500FT (0-1370m)
22,000 BTU/h
17,500 BTU/h
MANIFoLD pRESSuRE: 3.5" (9MB) WATER COLUMN
pRESSIoN Au CoLLECTEuR: 3.5" (9 MB) D'UNE COLONNE D'EAU
MINIMuM SuppLY pRESSuRE: 4.5" (11MB) WATER COLUMN
pRESSIoN D'ALIMENTATIoN MINIMALE: 4.5" (11MB) D'UNE COLONNE D'EAU
MAXIMuM SuppLY pRESSuRE: 13.0" (32MB) WATER COLUMN
pRESSIoN D'ALIMENTATIoN MAXIMALE: 13.0" (32MB) D'UNE COLONNE D'EAU
FoR uSE wITH GLASS DooRS
0
RECESSED DEPTH / PROFONDEUR D'ENCASTRE
0
VENT SIDES / COTES DE L'EVENT
0
VENT TOP / EVENT SUPERIEUR
0
VENT BOTTOM / EVENT INFERIEUR
2" *
RATING PLATE
.010 VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTER
TOLERANCES:
A
2
3
FOYER À GAZ VENTILÉ DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER,
UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS
MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE
ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU
CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU
CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES
FoR
MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
AvEC BARRIÈRE w565-0228. SuIvEZ LES INSTRuCTIoNS D'INSTALLATIoN SE
4001657 (NGZ)
TRouvENT DANS LE MANuEL D'INSTALLATIoN.
4001659 (WUSA)
CB46NTR
MoDEL
CB46pTR
B46pTR
CB46NTRE
CB46pTRE
B46pTRE
ALTITUDE / ELEVATION
0-4500FT (0-1370m)
INPUT / ALIMENTATION
22,000 BTU/h
REDUCED INPUT / ALIMENTATION REDUITE
19,000 BTU/h
MANIFoLD pRESSuRE: 10" (25MB) WATER COLUMN
pRESSIoN Au CoLLECTEuR: 10" (25MB) D'UNE COLONNE D'EAU
MINIMuM SuppLY pRESSuRE: 11" (27MB) WATER COLUMN
pRESSIoN D'ALIMENTATIoN MINIMALE: 11" (27MB) D'UNE COLONNE D'EAU
MAXIMuM SuppLY pRESSuRE: 13" (32MB) WATER COLUMN
pRESSIoN D'ALIMENTATIoN MAXIMALE: 13" (32MB) D'UNE COLONNE D'EAU
p4: 65%
p4: 65%
uN CoMBuSTIBLE SoLIDE NE DoIT pAS ETRE uTILISE AvEC
CET AppAREIL.
uTILISER AvEC LES poRTES vITREES
HoMoLoGuEES SEuLEMENT AvEC CETTE uNITE.
AvERTISSEMENT:
CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION RAPIDE.
REMPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL LTÉE.
N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
18"
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNERS
1"
INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS
3"
NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
1"
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST
IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU
SYSTEME DE PRISE D'AIR.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPPAREIL DE CHAUFFAGE.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: EP35
SERIAL NuMBER/No. DE SERIE:
UPDATED MAX. SUPPLY PRESSURE (NG)
MM/DD/YY: 03.21.16
3
5
4
pouR uNE uTILISER
B46TR
W385-2134 / A
Page 1 of 2
B46(N)TR(E) / B46(P)TR(E)
MM/DD/YY: 04.01.16
4
REV.
W385-2134
A
D
C
B
A
W385-2134_A
03.21.18_JK
JFK
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B46ptrB46ptreB46ntre

Table of Contents