16
3.6

DEfiNiTiONS

For the following symbols used in the venting calculations and examples are:
EN
> - greater than
> - equal to or greater than
< - less than
< - equal to or less than
h
- total of both horizontal vent lengths (hr) and offsets (ho) in feet
T
h
- combined horizontal vent lengths in feet
R
h
- offset factor: .03 (total degrees of offset - 90°*) in feet
O
V
- combined vertical vent lengths in feet
T
3.7

ELBOw vENT LENGTh vALUES

fEET
0.03
15°
0.45
30°
0.9
45°
1.35
90°*
2.7
* The fi rst 90° offset has a zero value and is shown in the formula as - 90°
W415-1613 / B / 06.13.16
iNChES
MiLLiMETERS
0.5
12.7
6.0
152.4
11.0
279.4
16.0
406.4
32.0
812.8