Example:
V
= 1.5 FT (0.5m)
1
V
= 5 FT (1.5m)
2
V
= V
+ V
= 1.5FT (0.5m)+ 5FT (1.5m) = 6.5 FT (2m)
T
1
2
H
= 1 FT (0.3m)
1
H
= 1 FT (0.3m)
2
H
= 10.75 FT (3.3m)
3
H
= H
+ H
+ H
= 1FT (0.3m) + 1FT (0.3m) + 10.75FT (3.3m) = 12.75FT (3.9m)
R
1
2
3
H
= .03 (four 90° elbows + one 45° elbow - 90°)
O
= .03 (360° + 45° - 90°) = 6.75 FT (2.1m)
H
= H
+ H
= 12.75FT (3.9m) + 6.75FT (2.1m) = 19.5 FT (5.9m)
T
R
O
H
+ V
= 19.5FT (5.9m) + 6.5FT (2m) = 26 FT (7.9m)
T
T
Formula 1:
H
< 3 V
T
T
3 V
= 3FT (0.9m) x 6.5FT (2m) = 19.5FT (5.9m)
T
19.5FT (5.9m) = 19.5FT (5.9m)
Formula 2:
H
+ V
< 40 FT (12.2m)
T
T
26 FT (7.9m) < 40 FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
3.11

REAR EXiT

FAILURE TO CREATE A SEAL TO THE FIREBOX WITH THE EXHAUST COLLAR ASSEMBLY WILL CAUSE
THE APPLIANCE TO FUNCTION IMPROPERLY AND CAN CAUSE INJURY OR PROPERTY DAMAGE.
A.
Remove the safety screen and glass front, refer to "
SAFETy SCREEN / DOOR REMOVAL AND INSTALLATION"
section.
Remove the contents from the firebox and set aside, you
B.
will need the exhaust flue collar from the top of the log
carton.
To ease assembly, remove the four hex head screws
C.
securing the deflector from inside the top front of the firebox, refer to Figure
1.
Place the gasket (provided) over the 4" (102mm) flue collar assembly and
D.
bend along perforation.
From inside the firebox, insert the 4" (102mm) flue collar through the back
E.
of the firebox. Install the rear exit shield onto the 4" (102mm) flue collar. See
"REAR ExIT ShIELD" section for installation instructions.
Secure the flue collar assembly, gasket and baffle bracket using the four hex head 3/8" thread
F.
cutting screws, refer to Figure 2. NOTE: Do not overtighten. The gasket needs only to be snug
against the firebox.
Reattach the deflector using the four screws and install the log set, glass door and safety screen.
G.
90°
H
2
V
1
H
1
90°
WARNING
!
fig. 1
45°
H
3
18.2_3A
DEFLECTOR
DÉFLECTEUR
W415-1613 / B / 06.13.16
23
EN
V
2
90°
fig. 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B46ptrB46ptreB46ntre

Table of Contents