9.0 ADjUSTMENT

9.1

PiLOT BURNER ADjUSTMENT

Adjust the pilot screw to provide properly sized fl ame. Turn in a
clockwise direction to reduce the gas fl ow.
Check Pressure Readings:
Inlet pressure can be checked by turning screw (A) counter-
clockwise 2 or 3 turns and then placing pressure gauge tubing
over the test point. Gauge should read as described on the chart
below. Check pressure with main burner operating on "hI".
Outlet pressure can be checked the same as above using
screw (B). Gauge should read as described on the chart
below. Check pressure with main burner operating on "hI".
AfTER TAKiNG PRESSURE READiNGS, BE SURE TO
TURN SCREwS CLOCKwiSE fiRMLY TO RESEAL. DO
NOT OvERTORqUE.
Leak test with a soap and water solution.
Prior to pilot adjustment, ensure that the pilot assembly
has not been painted. If overspray or painting of the pilot
assembly has occurred remove the paint from the pilot
assembly, or replace. Fine emery
cloth or a synthetic scrub pad (such as
Scotch-Brite™) can be used to remove
the paint from the pilot hood, electrode
and fl ame sensor.
*Maximum inlet pressure
not to exceeed 13".
A
ELECTRONiC
9.2

vENTURi ADjUSTMENT

This appliance has an air shutter that has been factory set open according
A
to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carbonization. Opening the air shutter will
cause a more blue flame, but can cause flame lifting from the burner ports.
The flame may not appear yellow immediately; allow 15 to 30 minutes for
the final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
Pressure
Inlet
Outlet
B
PILOT SCREW
B
VIS DU PILOTE
vENTuRI ADJuSTMENT CHART
FuEL
NG
1/8" (3.2mm)
LP
3/16" (4.8mm)
A
3/8" - 1/2"
(9.5mm - 12.7mm)
FLAME
SENSOR
Natural Gas
Natural Gas
(inches)
(millibars)
*
7"
17.4mb
(MIN. 4.5")
(MIN. 11.2mb)
3.5"
8.7mb
(9,5mm - 12,7mm)
MiLLivOLT
B46
Top
REAR
1/8" (3.2mm)
3/8" (9.5mm)
B
ELECTRONiC
iLLUSTRATED
PILOT SCREW
PILOT
ELECTRODE
BURNER
FLAME MUST ENVELOP
UPPER 3/8" (9.5mm) TO 1/2"
(12.7mm) OF FLAME SENSOR
Propane
Propane
(inches)
(millibars)
ÉLECTRODE
32.4mb
13"
VEILLEUSE
(MIN. 27.4mb)
(MIN. 11")
3/8" - 1/2"
10"
24.9mb
LA SONDE
39.1E
DE FLAMME
LA FLAMME DOIT
ENVELOPPER LA PARTIE
SUPÉRIEURE DE LA SOND
DE FLAMME DE 3/8" (9,5mm
À 1/2" (12,7mm)
VENTURI
BURNER
AIR
SHUTTER
OPENING
ORIFICE
49.1
W415-1613 / B / 06.13.16