Draft Diverter Connection; Flueing - Regency I43-NG1 Owners & Installation

Table of Contents

Advertisement

DRAFT DIVERTER CONNECTION

1)
Attach the fl ue to the fl ue collar on the detachable draft
diverter. The fl ue collar of the appliance will fi t inside a
standard 100mm fl ue and may be fastened directly to the
fl ue by sheet metal screw.
2)
Before pushing the appliance into position inside the
fi replace, align the draft diverter with the guides on the
inbuilt top and push forward. While pushing the unit back
into place keep pulling the draft diverter forward until the
screw hole in the spill tube-rear aligns with the screw hole
in the spill tube-front. (If screw holes do not line up then
draft diverter is not positioned correctly.) Secure the two
spill tubes with a screw.
Note: Final gas connection should be after unit is in place
to avoid damage to line when pushing the unit into
position.
Regency I43-1 ULTIMATE Gas Inbuilt Fireplace

FLUEING

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIM-
NEY FLUE SERVING A SEPARATE SOLID FUEL BURNING
APPLIANCE.
This appliance is designed to attach to a 100mm diameter fl ue
or approved aluminum fl ex liner running the full length of the
chimney. A minimum fl ue height of 3.6 m is recommended.
B-Vent must be supported by a fl ue support - supplied by fl ue
manufacturer. There must be at least 0.9 m of chimney above
the roof level.
Stack the pipe onto your fi nish support to a minimum height
of 0.9m above the roof penetration, or 0.6m above any point
within 3m measured horizontally. B-Vent chimneys require a
25mm clearance to combustibles.
The Regency Inbuilt incorporates its own internal draft diverter,
so no additional external draft diverter is required. Periodically
check that the fl ue is unrestricted and an adequate draft is
present when the unit is in operation. (See page 11 for spill-
age test.)
Before installing fl ue system ensure that the damper plate is
locked into the open position and secure to prevent the damper
plate from falling down and crushing the liner.
INSTALLATION