Maintenance - Regency I43-NG1 Owners & Installation

Table of Contents

Advertisement

IMPORTANT
MAINTENANCE INSTRUCTIONS
SERVICE ANNUALLY ONLY BY AN
AUTHORISED PERSON
1)
Clean the burner and control compartment of lint and
house dust by brushing and vacuuming at least once
a year. When cleaning the logs, use a soft clean brush
as the logs are fragile and easily damaged.
During the annual service the burners should be re-
moved from the burner tray and cleaned. Replace logs
and embers as per instructions on page 13.
2)
Clean glass (never when unit is hot), appliance, door and
louvres with a damp cloth. Never use an abrasive cleaner.
The gold louvres (and optional gold door) may be scratched
if abrasives are used to clean them.
The heater is fi nished in a heat resistant paint and should
only be refi nished with heat resistant paint (not with wall
paint). Regency uses Stove Brite Paint - Metallic Black
#6309.
3)
Make a periodic check of burner for proper position and
condition. Visually check the fl ame of the burner periodically,
making sure the fl ames are steady; not lifting or fl oating.
If there is a problem, call an authorised service person.
4)
The appliance and fl ueing system must be inspected
before use, and at least annually, by an authorised fi eld
service person, to ensure that the fl ow of combustion and
ventilation air is not obstructed.
5)
Keep the area near the appliance clear and free from
combustible materials, gasoline, aerosols, and other fl am-
mable vapours and liquids.
CHILDREN AND ADULTS SHOULD BE ALERTED TO
THE HAZARDS OF HIGH SURFACE TEMPERATURES,
ESPECIALLY THE FIREPLACE GLASS, AND SHOULD
STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
CLOTHING OR OTHER FLAMMABLE MATERIAL
SHOULD NOT BE PLACED ON OR NEAR THE
APPLIANCE.
CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED
FOR SERVICING AN APPLIANCE MUST BE REPLACED
PRIOR TO OPERATING THE APPLIANCE.
6)
Each time the appliance is lit, it may cause condensation
and fog the glass. This condensation and fog is normal
and will disappear in a few minutes as the glass heats up.
Never operate the appliance without the glass properly
secured in place or with the door open.
Regency I43-1 ULTIMATE Gas Inbuilt Fireplace
7)
Periodically check the pilot fl ames. Correct fl ame
patfl ames, not coming into proper contact with the rear
burner or thermopile or thermocouple. tern has three
strong blue fl ames: 1 fl owing around the thermopile,
1 around the thermocouple and 1 fl owing across the
burner (it does not have to be touching the burner).
Top View of pilot fl ame.
Incorrect fl ame pattern will have small, probably yellow
fl ames that do not come into proper contact with the rear
burner of the thermopile or thermocouple.
Top View of pilot fl ame
Note: If you have an incorrect fl ame pattern, contact your
Regency dealer for further instructions.