MAINTENANCE

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the
gas valve and allow the unit to cool before opening door to
carefully remove the logs. The pilot light generates enough
heat to burn someone. If for any reason a log should need
replacement, you must use the proper replacement log. The
position of these logs must be as shown in the diagram under
Log Installation.
NOTE: Improper positioning of logs may create
carbon build-up and will alter the unit's performance
which is not covered under warranty.
GOLD-PLATED DOORS
The 24 carat gold plated fi nish on the door requires little main-
tenance, and need only be cleaned with a damp cloth. DO
NOT use abrasive materials or chemical cleaners, as they may
harm the fi nish and void the warranty. Clean any fi ngerprints off
before turning the unit on. If gasket seal is not tight - door
may discolour.
DOOR GASKET AND
GLASS GASKET
If the door gasket requires replacement use 7/8" diameter oval
door gasket . The glass requires 7/8" fl at glass gasket. See
your Regency Dealer.

LATCH ADJUSTMENT

The door latch may require adjustment as the door gasket
material compresses after a few fi res and after glass replace-
ment. Turn the adjustable latch to tighten or loosen the latch.
20

GLASS REPLACEMENT

Your Regency stove is supplied with high temperature, 5 mm
Neoceram ceramic glass that will withstand the highest heat
that your unit will produce. In the event that you break your
glass by impact, purchase your replacement from an authorised
Regency dealer only, and follow our step-by-step instructions
for replacement.
Removing Glass
Note: Wearing gloves will protect your hands while han-
dling glass.
1)
Remove the safety screen (Australia only). Remove the
door from the unit and place on a soft surface to prevent
scratching.
2)
Pull out the door gasket.
3)
Remove the 24 nuts holding the glass retainers in place.
Do not remove the nuts underneath the retainers.
4)
Remove the door catch plate.
5)
Remove glass retainers on sides fi rst (3 each side) then
remove two center retainers.
Note: Center glass retainers are glued to center glass.
6)
Remove glass from extrusions. When removing center
glass, leave white insulation in place.
Note: Safety
screen in Aus-
tralia only.