A-12 Host error messages
ERR: Protocol missing, specify 3270 or VT100
ERR: Incorrect syntax for ping action
ERR: Invalid Protocol xxx, protocol
ERR: Invalid entry non-numeric
ERR: A board # was not specified in the trs.conf
ERR: Possibly exceeded number of allowable boards
555-9001-316 Standard 1.0 February 1996
The protocol type was missing from the trs.conf protocol
Meaning:
field.
Make sure that '3270' or 'vt100' is specified in the protocol
Action to take:
field.
The heartbeat action template was specified incorrectly in
Meaning:
the trs.conf file.
Revise the trs.conf file so that the heartbeat field has the
Action to take:
correct syntax.
xxx is an invalid protocol.
Meaning:
Revise the trs.conf file so that the protocol is either '3270'
Action to take:
or 'vt100'.
A non-numeric symbol occurred in the board number or
Meaning:
session number field of the trs.conf file.
Check the syntax of the trs.conf file.
Action to take:
The board number was missing from the board field of the
Meaning:
trs.conf file.
Check the syntax of the trs.conf file.
Action to take:
The number of total boards defined in the trs.conf file
Meaning:
exceeds the total number of boards the system allowed.
Revise the trs.conf file and make sure the total board
Action to take:
number does not exceed the maximum allowed which is 4.