Disconnecting The Cables - Nortel BSG12aw Installation Manual

Business services gateway
Hide thumbs Also See for BSG12aw:
Table of Contents

Advertisement

1
Remove all of the cables from the unit.
To disconnect cables, see
2
If a unit is mounted to the top of another unit, slide that unit forward until it
disengages from the clips on the lower unit. Lift the unit off of the top of the lower
unit.
3
Lift the unit off of the table.
4
Set the unit on a flat, clean, static-free surface.

Disconnecting the cables

Use this procedure to disconnect the cables from a BSG8ew/12ew/aw/tw.
Procedure steps
Step
Action
1
Remove the FXO RJ-11 connection.
2
Remove the FE connections from the LAN ports.
3
Remove the WAN connection from the WAN ports.
4
While disconnecting a BSG8ew, rotate the power supply retention clip to free the
power supply cord.
5
Remove the power supply cord from the unit.
Caution: Risk of leakage currents
You must disconnect the telephony and data networking cables from the system
before disconnecting the power cord from a grounded outlet.
Connecting the cables
For connecting the cables, see
"Disconnecting the cables" on page
End
End
"Cable connection" on page
Basic procedures
65.