BenQ SX930 Service Manual page 169

Hide thumbs Also See for SX930:
Table of Contents

Advertisement

Un-package Shock
(Non-operating)
Bench Drop
Security Lock
B2.2 Atmospherics Test
Temperature/Humidity,
(Operating)
Storage High Temperature /
Humidity
(Non-operating, with package)
Altitude
Start
B2.3 Regulatory
EMC
ESD
ESD : Air
ESD : Contact
Surge
Safety
20 ~ 200
Duration : 5 Minutes
Axis : 3 axis ( Horizontal and Vertical axis ,Z axis)
Duration: 5 minutes per orientation, totally 15 minutes.
Waveform: Half sine
Faces: 6 sides/per orientation, 3 shocks
Duration: < 20 ms
Velocity accelerate: 50 G
1. Pivot, 90 degree, sitting on right and left side, 1 drop per
orientation, total of 2 drops.
2. Bottom and opposite, 1 drop per orientation, drop height 5 cm,
totally 2 drops.
20kg break away force
Test condition: 0℃~ 40℃, 10%~90%, no condensation
Test procedure:
25℃/90%, 2hrs → 40℃/90%, 6hrs → 0℃, 6hrs →
40℃/10%, 6hrs → 25℃/90%, 2hrs; (2 Cycles)
Test condition: (-20°C ~ 60°C, 10% ~ 90% R.H.)
1. Storage high temperature / humidity exposure test:
25℃/60%, 1hrs → 60℃/90%, 48hrs → 25℃/60%, 1hrs
2. Storage transportation test:
25℃/60%, 1hrs → -20℃, 24hrs → 25℃/60%, 1hrs →
60℃/90%, 24hrs → 25℃/60%, 1 hrs
Criteria Inspection:
1. The products should be operated normally at specified lower and
higher temperature environment.
2. The carton no crash and broken issue.
Operating:
Without high altitude mode 0°C~35°C @ 0~1499m above sea level
With high altitude mode 0°C~30°C @ 1500~3000m above sea level
Non-operating:
30℃@0~12,200m above sea level
Turn On @ 0℃ and 40℃, AC90~264V, 47~63Hz
Test condition:
FCC part 15B class B, EN55022 class B
Follow IEC 61000-4-2 and EN55024 regulation
1. Input Voltage / Frequency : 110V AC / 60Hz
2. Timing Mode : 48K/72Hz, Full White Pattern
Air discharge to set surface: ±15KV
Contact discharge to set surface and metal:
±8KV
Contact discharge to Vert./Horiztl coupling
plane: ±8KV
Contact discharge to D-sub/S-video input pins:
±4KV
Contact discharge to HDMI input pins: ±2KV
1KV line to line, 2KV line to ground on input power lines.
Please refer to IEC/EN/UL 60950-1 for details.
169
0.0185
No Damage
No Damage
No Damage
No Error
No Error

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents