HORIZONTAL TERMINATIONS

" (
RIGID PIPE 4" X 6-5/8
The diagrams below shows examples of horizontal termination arrangements using one 90
1) A maximum of one 90
or two 45
o
2) Minimum distance between elbows is 305mm.
Maintain clearances to combustibles as listed in the "Clearances" section.
Horizontal vent must be supported every 0.9m.
Must use optional rigid pipe adaptor (Part# 510-994) when using Duravent systems.
A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
Flex system can only be used up to 3m - otherwise rigid flueing must be used.
Straight Out Horizontal Venting
center
of hole
C L
Please note the minimum centerline for
basic install shown above.
Regency GF900L-1 Gas Fireplace
102MM X 175MM)
elbows is permitted.
o
Diagram 1
C L
o
elbow.
installation