FLUE RESTRICTOR POSITION

FLUE RESTRICTOR SETTING
Regency GF900L-1 Gas Fireplace
Flue restriction is required for certain venting installations, see the diagrams
in the "Flueing
Arrangements" section to determine if they are required for your installation.
The Flue Restrictor plate is located on the inside top of the firebox.
To set the flue restriction as indicated in the flueing arrangements diagrams,
refer to the following instructions;
Set 3-(32mm)
1. Remove the glass door and inner panels - see instructions in this manual.
2. Remove 6 screws (3 front - 3 back) to remove heat baffle to access restrictor
plate.
3. Remove the screws that hold the flue restrictor in place.
Set 2- (41mm)
4. Adjust the flue restrictor plate to the required flue restrictor position as per
the diagrams shown below.
Set1-(44mm)
5. Once the flue restrictor plate is in the required position, secure with screws.
Set-0 (108mm)
FULLY OPEN
FACTORY SETTING
installation
Heat Baffle
17