8. Remove burner by removing 2 screws at the back of the burner in
locations shown below.
Diagram 5 - Burner Screw Locations
9. Pull off the pilot cap to expose the pilot
orifice (see right).
.
10
Unscrew the pilot orifice with the Allen key and replace
with the LPG pilot orifice in the kit and replace pilot cap
(see right).
11. Remove burner orifice with a 12mm spanner and discard. Use another
spanner to hold on to the elbow below the orifice.
919-131a
Regency GF900L-1 Gas Fireplace
Pilot Cap
Pilot Orifice
Diagram 4 - Remove Pilot Cap
12. Reinstall new burner orifice LP stamped #53 or ULPG burner orifice
stamped #53 and tighten.
13. Replace the yellow "NG" label with the red "ULPG" label.
14. Carefully pull out the control box.
NOTE: The control box is held in place with velcro.
15. Remove the heat shield from the control box by removing the 2
screws.
16. Remove the control box cover by undoing the 3 screws.
Manoeuvre through antenna.
17. Remove the jumper using pliers.
Jumper
18. Reverse steps 17, 16, 15, 9, for both units. For GF900C reverse Steps
8-6 and Step 1. For GF900L reverse steps 5-1.
19. Adjust the air shutter opening (See page 28 for Aeration Adjustment)
20. Turn on gas supply and plug in power cord.
21. Adjusting the Outlet Pressure