Temperature; Extinguishing; Температура Горячей Воды; Выключение - Biasi PARVA CONTROL M90.24AV User Manual And Installation Instructions

Table of Contents

Advertisement

Instruction for use
От 5 До 15
градусоь
From 5°C to
15°C
Your qualified installer will be able to
recommend the most suitable adjustment for
your system.
The temperature and pressure gauge (4, Fig.
1.3) will allow you to check that the set
temperature is obtained.
2.5. D.h.w. temperature
The temperature of the D.h.w. storage tank
can be varied by turning the knob 8 to a
maximum of about 60 °C (Fig. 2.8)
8
Minimum
vbybvev
Where the amount of limescale present in the
water may be particularly great, it is advisable
to install a small water treatment device or
softener.

2.6. Extinguishing

To turn the boiler off set the function selector
7 to the position shown in Fig. 2.9.
The appliance operation light 9 will flash
every 4 seconds.
8
Between -5°C and
+5°C
Между-5°C и
+5°C градусами
Lower than -
5°C
Менее -5°C
градусоь
Fig. 2.7
Квалифицированный
монтажник
посоветует Вам, как выбрать наиболее
подходящую
настройку
для
системы.
Термоманометр (4, рис. 1.3) поможет Вам
проконтролировать получение заданных
температур.
2.5 Температура горячей воды.
Температура в накопительном бойлере
для горячей воды может изменяться путем
поворота
регулятора
8
до
температуры около 60ûС.(рис.2.8)
8
Maximum
vfrcbvev
Fig. 2.8
В случаях, когда в воде присутствует
большое
количество
примесей,
рекомендуем устанавливать небольшие
системы водоподготовки или умягчители
воды.
2.6 Выключение
Чтобы
выключить
котел,
переместите
переключатель 7 в положение, указанное
на рис. 2.9. Индикатор котла 9 будет
моргать каждые 4 секунды.
5
Set the d.h.w. and c.h. temperature
control knobs to their maximum position.
6
Switch on the boiler and if external
controls are fitted (Timeclock, room
thermostat ) ensure they "call for heat".
7
Check the maximum gas pressure and
compare the value on the gauge with the
value indicated in the section 4.4 (gas
pressures at the burner), accordingly with
the model of boiler installed.
8
To
adjust
Вашей
maximum gas pressure adjustment (A in
Fig. 6.5)until you obtain the required
pressure
pressure increases).
9
Check the maximum gas flow at the gas
meter and compare the value indicated in
the section 4.4 (gas rate), accordingly
макс.
with the model of boiler installed.
10 Switch off the boiler.
11 Disconnect the gas modulator coil by
removing the electrical connector B Fig.
6.5).
мы
9
12 Switch on the boiler.
5
Установите
температуры
отопления
значения.
6
Включите котел и в случае, если к
нему
устройства
термостат), удостоверьтесь, что они
находятся в режиме "запрос тепла".
7
Проверьте максимальное давление
газа и сравните его значение со
значениями, указанными в разделах
4.5 (давление газа на горелке), в
соответствии
установленного котла.
the
pressure
rotate
the
8
Чтобы
поворачивайте
максимальное давления газа (С на
(by
rotating
clockwise
the
рис.6.5) до тех пор, пока не получите
необходмые
вращении по направлению часовой
стрелки, давление возрастает).
9
Проверьте
газа на газовом счетчике и сравните
значения, указанные в разделах 4.5
(расход
моделью установленного котла.
10
Выключите котел.
11
Отключите модулирующую газовую
катушку, отсоединив электрический
контакт В (рис. 6.5).
7
6
5
Fig. 6.4
12
Включите котел.
Commissioning
рукоятки
регулировки
горячей
воды
и
на
максимальные
подключены
внешние
(таймер,
комнатный
с
моделью
увеличить
давление,
регулятор
показатели
(при
максимальный
расход
газа),
в
соответствии
с
Fig. 6.5