Biasi PARVA CONTROL M90.24AV User Manual And Installation Instructions page 5

Table of Contents

Advertisement

Maintenance
3
Loosen the screws B. Bring the bottom of
the panels away from the boiler and lift
them, freeing them from the top hooks
(Fig. 8.2).
8.3. Emptying the ch. system
1
Close the c.h. isolating valves.
2
Open the central heating drain cock (17 in
Fig. 8.3).
8.4. Cleaning the primary heat
exchanger
Take off the front panel of the case, then the
sealed chamber lid and the front panel of the
combustion chamber.
If you notice dirt on the fins of the primary
heat exchanger (30 on section 4.1), cover the
sloping surfaces of the burner (28 on section
4.1) entirely in a protective layer (sheets of
newspaper or similar). Brush out the primary
heat exchanger (30 on section 4.1) with a
bristle paintbrush.
8.5. Checking the pressurisation in
the expansion vessel
Empty
the
central
heating
system
as
described in section 8.3 of this chapter and
check that the pressure in the expansion
vessel is not less than 1 bar.
See also section 4.6 of this manual.
If the pressure should be lower, take steps to
correct the pressure level.
42
3
Ослабьте винты В. Вытащите нижние
части
панелей
из
котла
приподнимите
их,
освободив
верхних крючков (рис 8.2).
17
Fig. 8.3
8.3 Опорожнение системы
отопления
1
Закройте кран подачи отопления.
2
Откройте
сливной
кран
отопления (17 на рис.8.3).
8.4 Чистка первичного
теплообменника
Снимите переднюю панель корпуса, затем
крышку герметичной камеры и переднюю
панель камеры сгорания.
Если Вы обнаружили загрязнения на
ребрах первичного теплообменника (30 на
разделе
4.1),
полностью
наклонную поверхность горелки (28 на
разделе 4.1) листом бумаги или газетой.
Очистите первичный теплообменник (30
на разделе 4.1) при помощи кисти из
щетины.
8.5 Проверка предварительного
давления в расширительном
баке
Опорожните
систему
отопления,
указано в разделе 8.3 этой главы, и
проверьте,
чтобы
давление
расширительном баке было не менее 1
бара.
Смотрите
также
раздел
настоящего руководства.
Если
давление
окажется
предпримите
шаги,
чтобы
исправить
уровень давления.
! If the boiler is fitted with a digital
programmer, when setting the times for
и
automatic operation, remember that for
от
every "ON" time there must be an "OFF"
time to follow and that on every occasion
you enter a time you must also indicate
which days that you want the boiler to
follow the timed settings.
! Some products incorporate an anti cycling
time delay. It is normal when first
switching the boiler on for the boiler to
operate on heating for a few seconds
then switch off. After 3-4 minutes has
elapsed the boiler will then re ignite and
operate perfectly normally. The ignition
delay cycle does not prevent normal
operation of the boiler to provide d.h.w.
! If you are in any doubts as to the
installation or operation of the boiler
please read the instruction manuals
thoroughly and then if necessary contact
a competent service agent.
системы
Appliance category II
mbar, G30 29 mbar, G31 37 mbar
This appliance conforms with the EEC directive
90/396 and, consequently, it has the right to make
use of the CE brand name
Moreover, the appliance conforms with the EEC
directive 87/308 relative to the prevention and
elimination of radio disturbances.
The appliance is build to comply with the
regulation now in force regarding gas appliance's
закройте
safety and the European regulation now in force
relative to safety of household and similar
electrical appliances.
The manufacturer, in the continuous pocess to
improve his products, reserves the right to modify
the data expressed in the present documentation
at any time and without prior notice.
The present documentation is an informative
support and it cannot be considered as a contract
towards third parties.
как
в
Abbreviations used in the manual: = Сокращения, используемые в данном руководстве:
4.7
C.h. = Central heating = Система отопления
D.h.w. = Domestic hot water = Горячая вода для бытовых нужд
ниже,
C.h.w. = Domestic cold water = Холодная вода для бытовых нужд
! Если котел оснащен программируемым
устройством, при выборе времени для
его
автоматической
забывайте,
включения
соответствующим
выключения, Вы также должны указать
дни,
в
которые
автоматически работать.
! Некоторые
антициклической задержки времени.
Это
нормально,
включается на отопление на несколько
секунд,
а
прошествии 3-4 минут котел снова
запускается и работает в нормальном
режиме. Задержка включения котла не
мешает
функционированию
приготовление горячей воды.
! Если
у
Вас
сомнения или вопросы по установке
или использованию котла, прочтите
внимательно инструкцию, а в случае
необходимости
сервисный центр.
Gas G20 20
Устройство категории II2H3+ газ G20 20
2H3+
мбар, G30 29 мбар, G31 37 мбар.
Этот прибор соответсвует директиве ЕЕС
90/396 и на него может наноситься знак
маркировки СЕ.
Кроме того, прибор соответсвует директиве
ЕЕС 87/308, относящейся к предотвращению и
устранению радиопомех.
Прибор совместим со всеми стандартами,
касающимися газовой безопасности и с
Европейскими нормами бытовой и
электрической безопасности.
Изготовитель оставляет за собой право,
вследствии усовершенствования данного
прибора, вносить изменения в настоящее
техническое руководство в любое время и без
предварительного уведомления.
Настоящая документация является
информационным приложением и не может
рассматриваться как контракт по отношению к
третьим лицам.
работы,
не
что
каждое
время
должно
сопровождаться
временем
его
котел
должен
котлы
имеют
функции
когда
котел
затем
отключается.
По
нормальному
котла
на
возникли
какие-либо
обратитесь
в

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents