Flueing Arrangement For Vertical Terminations - Regency Greenfire GF1500L-NG Owners & Installation Manual

Hide thumbs Also See for Greenfire GF1500L-NG:
Table of Contents

Advertisement

installation

FLUEING ARRANGEMENT FOR VERTICAL TERMINATIONS

Vertical Flue with One(1) 90
The shaded area in the diagram shows all allowable combinations
of straight vertical and offset to vertical terminations, using two
bends, with Rigid Pipe Flueing Systems.
45
o
Flue must be supported at offsets.
Minimum distance between 45
Maintain clearances to combustibles as listed in the
"Clearances" section.
Horizontal vent must be supported every 1M.
Must use optional rigid pipe adaptor (Part# 770-994)
when using rigid pipe flue systems (Dura Vent Only).
Refer to the "Flue Restrictor Position" section for details
on how to change the flue restrictor from the factory
setting of Set 0 to Set 1, Set 2 or Set 3 if required.
Vertical flue must terminate a minimum of 600m to the
underside of the cowl from the nearest part of the roof,
as per AS/NZS 5601-2013
"THIS UNIT MUST ALWAYS
TERMINATE / FLUE
DIRECTLY TO THE OUTDOORS."
22
Elbows (1 - 90
2 - 45
o
o =
bends is 305mm.
o
)
o
Regency GF1500L Gas Fireplace