Technical Specifications - Johnson Controls TEC2216-4 Installation Instructions Manual

Table of Contents

Advertisement

Technical Specifications

TEC22x6(H)-4 and TEC22x6H-4+PIR Series L
Dehumidification Capability, Fan Control, and Occupancy Sensing Capability
Power Requirements
Triac Output
On/Off and
Rating (BO1,
Floating
BO2, BO3,
Control
BO4)
Analog Output
Proportional
Rating
Control
Fan Relay Output Rating
Auxiliary
Triac Output
Output Rating
Analog Inputs
Binary Inputs
Temperature Sensor Type
Wire Size
L
W
Network Standard
ON
ORKS
Temperature
Backlit Display
Range
Heating
Control
Cooling
Control
Accuracy
Temperature
Humidity
Minimum Deadband
Ambient
Operating
Conditions
Storage
Compliance
United States
Canada
Europe
Australia and
New Zealand
Shipping Weight
The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these
specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or
misuse of its products.
24
TEC22x6(H)-4 and TEC22x6H-4+PIR Series L
Dehumidification Capability, Fan Control, and Occupancy Sensing Capability Installation Instructions
Published in U.S.A.
ON
19 to 30 VAC, 50/60 Hz, 2 VA (Terminals 4 and 5) at 24 VAC Nominal, Class 2 or
Safety Extra-Low Voltage (SELV)
19 to 30 VAC, 1.0 A Maximum, 15 mA Minimum, 3.0 A In-Rush
0 to 10 VDC into 2k ohm Resistance (Minimum)
19 to 30 VAC, 1.0 A Maximum, 15 mA Minimum, 3.0 A In-Rush
19 to 30 VAC, 1.0 A Maximum, 15 mA Minimum, 3.0 A In-Rush
Resistive Inputs (RS and UI3) for 10k ohm Johnson Controls Type II Negative
Temperature Coefficient (NTC) Thermistor Sensors
Voltage-Free Contacts across Terminal Scom to Terminals BI1, BI2, or UI3
Local 10k ohm NTC Thermistor
Unshielded Twisted Pair - 22 AWG (0.6 mm Diameter) Minimum, 18 AWG (1.0 mm
Diameter) Recommended
64 Devices Maximum without a Repeater, 127 Devices Maximum with a Repeater;
6,250 ft (1,905 m) Maximum (Bus Topology)
-40.0°F/-40.0°C to 122.0°F/50.0°C in 0.5° Increments
40.0°F/4.5°C to 90.0°F/32.0°C
54.0°F/12.0°C to 100.0°F/38.0°C
±0.9F°/±0.5C° at 70.0°F/21.0°C Typical Calibrated
±5% RH from 20 to 80% RH at 50 to 90°F (10 to 32°C)
2F°/1C° between Heating and Cooling
32 to 122°F (0 to 50°C); 95% RH Maximum, Noncondensing
-22 to 122°F (-30 to 50°C); 95% RH Maximum, Noncondensing
UL Listed, File E27734, CCN XAPX,
Under UL 873, Temperature Indicating and Regulating Equipment
FCC Compliant to CFR 47, Part 15, Subpart B, Class A
L
M
® Certification 3.4
ON
ARK
UL Listed, File E27734, CCN XAPX7, Under
CAN/CSA C22.2 No. 24, Temperature Indicating and Regulating Equipment
Industry Canada, ICES-003
CE Mark, EMC Directive 2004/108/EC, standards EN 61000-6-3 and EN 61000-6-1
C-Tick Mark, Australia/NZ Emissions Compliant
TEC22x6(H)-4 Models: 0.75 lb (0.34 kg)
TEC22x6H-4+PIR Models: 0.77 lb (0.35 kg)
Metasys® and Johnson Controls® are registered trademarks of Johnson Controls, Inc.
All other marks herein are the marks of their respective owners. © 2010 Johnson Controls, Inc.