Fip1.5 Main Motor Error - Oki B6500 Troubleshooting Manual

Hide thumbs Also See for B6500:
Table of Contents

Advertisement

FIP1.5 Main Motor Error

Step
Possible causes:
MAIN MOTOR (PL11.1.2) GEAR ASSY HOUSING
(PL11.1.3)
GEAR ASSY PLATE (PL11.1.10)
LVPS (PL12.1.5)
HVPS/MCU (PL12.1.19)
Checking MAIN MOTOR installation
1
Are MAIN MOTOR, GEAR ASSY HOUSING and GEAR
ASSY PLATE installed correctly?
Checking MAIN MOTOR for operation
Does the MAIN MOTOR rotate, and each gear rotate
2
normally?
Check using Chapter 2 Diagnostic [Main Motor Test].
Remove COVER LEFT (PL1.1.6) to check.
Checking GEAR ASSY HOUSING and GEAR ASSY
PLATE for operation.
3
Does each gear rotate normally?
Rotate and check each gear of GEAR ASSY HOUSING
and GEAR ASSY PLATE.
Check
1 – 15
Chapter 1 Troubleshooting
Yes
With tool Go to
Reinstall obstruc-
step 2. Without
tool Go to step 3.
Replace HVPS/
MCU.
Go to step 3.
(RRP12.10)
Go to FIP1.25
MAIN MOTOR.
obstructive parts.
No
tive parts.
Replace the

Hide quick links: