• Scroll the various parameters using keys 13
or 14 until the LCD display indicates the let-
ters P10 and the value of the parameter, in-
dicating entry in "parameter 10" (Figure 5.44).
Figure 5.44
• It is possible to modify the value of param-
eter 10 between 00=0s to 100=510s using
keys 10 or 11 (each unit increase or decrease
on the display corresponds to 5 seconds). E.g.
36=180 seconds.
• By pressing key 12 (Figure 5.42) confirmation
of the inserted value is obtained.
• By pressing keys 12 and 13 together (Figure
5.42) you will exit without changing the value
(return to the parameter list Figure 5.44).
• Press keys 12-13-14 together for 10 seconds
(Figure 5.42) to exit "programming mode".
REMOTE programming
Via REMOTE programming you can select a
minimum time between two ignitions when
the boiler is operating in normal on/off heat-
ing mode.
• Press the button
to enter
mode (Figure 5.45).
INSTALLATION
for more than 3 seconds
0
21
3
1
8
6
1 5
9
1
2
Figure 5.45
• Press buttons
and
ter transparent programming (Figure 5.46).
Figure 5.46
• Press buttons
"PM10" program for selecting ignition fre-
quency (Figure 5.47).
Figure 5.47
Figure 5.47 shows a programmed SET of 90,
which corresponds to a re-ignition time of ap-
prox. 3 minutes.
The adjustment range is between 0 and 8 and
together to en-
or
to display the
- 49 -