Gas Hook-Up - Nexgrill Stainless Steel Gas Grill 720-0050-LP Use And Care Manual

Stainless steel gas grill
Table of Contents

Advertisement

GAS HOOK-UP

Only the pressure regulator and hose assembly
supplied with the grill should be used. Any
replacement pressure, regulator and hose
assembly must be specified by the grill
manufacturer.
This is a liquid propane configured grill.
Do not attempt to use a natural gas supply unless
the grill has been pre-configured for natural gas
use.
Total gas consumption (per hour) of 720-0050-LP
grill with all burners on "HI":
Main burners
48,000 Btu/hr.
Side burner
12,000 Btu/hr.
Rotisserie burner 10,000 Btu/hr.
Total
The installation of this appliance must conform with
local codes or, in the absence of local codes, with
the national fuel gas code, ANSI Z223.1 Installation
in Canada must be in accordance with the
Standard CAN/CG A-B149.2 (installation code for
gas burning appliances and equipment) and local
codes.
LP Gas Cylinder Requirements (20lb.Cylinder)
A dented or rusty LP Gas Cylinder may be
hazardous and should be checked by your LP
supplier. Never use a cylinder with a damaged
valve. The LP gas cylinder must be constructed
and marked in accordance with the specifications
for LP gas cylinders of the U.S. Department of
Transportation (DOT), or the National Standard of
Canada, CAN/CSA-B339, Cylinders, Spheres and
Tubes for Transportation of Dangerous Goods; and
Commission.
The 20lb. cylinder must be provided with a shut off
valve terminating in an LP gas supply cylinder
valve outlet specified, as applicable, for connection
type QCC1 is the standard for compressed gas
cylinder
valve
outlet
ANSI/CGA-V-1.
The cylinder supply system must be arranged for
vapor withdrawal. The cylinder must include a
collar to protect the cylinder valve.
Manifold pressure: (operating): 10" water column
(W.C.), (non-operating): 11.2" water column (W.C.).
70,000 Btu/hr.
and
inlet
connection
LP Gas Cylinder must be fitted with Overfill
Protection Device (OPD).
LP GAS HOOK-UP:
Ensure that the black plastic grommets on the LP
cylinder valve are in place and that the hose does not
come into contact with the grease tray or the grill
head.
CONNECTION:
Your grill is equipped with gas supply orifices for use
only with liquid propane gas. It is also equipped with
a
high
capacity
connection to a standard 20lb. LP cylinder (18-1/4"
high, 12-1/4" diameter).
To connect the L.P. gas supply cylinder:
1. Make sure tank valve is in its full off position (turn
clockwise to stop).
2. Check tank valve to ensure it has proper external
male
threads
ANSIZ21.81).
3. Make sure all burner valves are in the off
position.
4. Inspect valve connections, port and regulator
assembly. Look for any damage or debris.
Remove any debris. Inspect hose for damage.
Never attempt to use damaged or obstructed
equipment. See your local LP gas dealer for
repair.
5. When connecting regulator assembly to the
valve, hand tighten the nut clockwise to a
complete stop. Do not use a wrench to tighten.
Use of a wrench may damage the quick coupling
nut and result in a hazardous condition.
6. Open the tank valve fully (counterclockwise). Use
a soapy water solution to check all connections
for leaks before attempting to light the grill. See
below. If a leak is found, turn the tank valve off
and do not use the grill until a local LP gas dealer
can make repairs.
To disconnect LP gas cylinder:
1. Turn the burner valves off.
2. Turn the tank valve off fully (turn clockwise to
stop).
Detach the regulator assembly from the tank valve by
turning the quick coupling nut counterclockwise
11
hose/regulator
assembly
(type
1
connection
for
per

Hide quick links: