Epson U590P Information Manual page 39

Hide thumbs Also See for U590P:
Table of Contents

Advertisement

CONFIDENTIAL
Drawer kick-out connector status (n=2, 50)
Bit
Off/On
Hex
Off
00
0
On
01
1-3
4
Off
00
5, 6
7
Off
00
Slip status (n=3, 51)
This command transmits the remaining printing area (times the number of dots for the internal
characters in vertical (9 dots)) by using the values from 00H to 06H. With the MICR reader model, the
status is 00H when the slip paper is not selected.
The Number of Remaining Dots
0 to 8
9 to 17
18 to 26
27 to 35
36 to 44
45 to 53
54 or more
DLE EOT n
[Name]
[Format]
[Range]
DLE EOT n transmits the specified status in real time. This command is ignored during a process of
transmitting the check paper reading result (only with the MICR reader). With a serial interface
model, this command is executed even when the printer is off-line, the receive buffer is full, or an
error occurs. With a parallel interface model, this command is not executed in the following status,
because the printer is busy and unable to receive data from the host computer:
Receive buffer is full when DIP switch 2-1 is set to ON.
Printer is off-line, an error occurs, or receive buffer is full when DIP switch 2-1 is set to OFF.
1-32 Command Descriptions
Decimal
Status
0
Drawer kick-out connector pin 3 is LOW.
1
Drawer kick-out connector pin 3 is HIGH.
Undefined.
0
Not used. Fixed to Off.
Undefined.
0
Not used. Fixed to Off.
Hex
00
01
02
03
04
05
06
Real-time status transmission
ASCII
DLE
Hex
10
Decimal
16
1 ≤ n ≤ 3 , n=5
Decimal
0
1
2
3
4
5
6
EOT
n
04
n
4
n
Rev. A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tm-u590

Table of Contents