Service Diagnostics and Procedures–Disassembly
Service Diagnostics and Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. Wires removed during disassembly must be replaced on proper terminals to insure
correct earth ground and polarization. After servicing, reconnect power using power switch.

Control Board Access

The range uses a control board to perform various
oven functions. As input is received by the board,
corresponding output actions are performed (relays
open/close).
To access Control Board:
1.
Remove screws and lift kick plate from keyhole
screws.
Kick Plate
2.
Remove keyhole screws and lower access grill
from range.
Lower Access Grill
Keyhole Screws
3.
Remove screws and slide control panel
assembly from range.
Note: During installation, make sure the tabs on the
control panel are aligned with the slots on the range.
4.
Reverse procedure for installation.
© 2010 Viking Preferred Service
Screws
Screws
Tabs
WARNING

Control Board Removal

Control Board Accessed
1. Mark and disconnect all connectors from control
board and capacitors.
Connectors
Connectors
Connectors
2. Place control board panel assembly on suitable
work surface.
3. The main control board, power board and
capacitors are replaced as one assembly.
4. Reverse procedure for installation.
Connectors
Capacitors
Connectors