Surface Igniter - Viking vdsc530t Service Manual

30" electronic control dual fuel range
Hide thumbs Also See for vdsc530t:
Table of Contents

Advertisement

Service Diagnostics and Procedures–Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect gas supply and electrical power to unit
before servicing. Discharge capacitor through a resistor before attempting to service. Wires removed during
disassembly must be replaced on proper terminals to insure correct earth ground and polarization. After
servicing, reconnect electrical power and gas supply. Before placing appliance into operation, always check
for gas leaks with soapy water solution. DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
Main Top Access (cont.)
7.
Remove landing ledge (see Landing Ledge
section, page 49).
8.
Remove Phillips head screws in front securing
the left and right side trims.
Screw
9.
Remove side trims and repair/replace
main top.
10. Reverse procedure to reinstall.
© 2010 Viking Preferred Service
WARNING

Surface Igniter

To access the surface igniters:
(follow steps 1 – 3 under Main Top Access, page 50)
Note: Igniters are not sold separately. Burner base
must be replaced which includes the igniter.
1.
Remove C-clip from igniter, spring, and clip.
C-clip
2.
Remove igniter from burner base and repair/
replace igniter.
Burner Base
3.
Reverse procedure to reinstall.
Igniter Spring
Igniter
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents