Warning Indicators

The ON/STANDBY or LAMP/COVER indicator lights up or flashes if there is any
trouble with your projector.
Symptom
LAMP/COVER flashes in
red. (A repetition rate of 2
flashes)
LAMP/COVER flashes in
red. (A repetition rate of 3
flashes)
ON/STANDBY flashes in
red. (A repetition rate of 4
flashes)
ON/STANDBY flashes in
red. (A repetition rate of 2
flashes)
ON/STANDBY flashes in
red. (A repetition rate of 6
flashes)
Note
When a warning indicator other than the above starts flashing, and the symptom persists even after
carrying out the above methods, consult with qualified Sony personnel.
60
ON/STANDBY indicator
LAMP/COVER indicator
Cause and Remedy
c Close the lamp door (inner cover) securely, then tighten the
screws securely (1 page 63).
c The temperature of lamp is unusually high. Turn off the power
and wait for the lamp to cool, then turn on the power again.
c If the symptom persists, the lamp may be at the end of its service
life. In this case, replace the lamp with a new one (1 page 62).
c The fan is broken. Consult with qualified Sony personnel.
c The internal temperature is unusually high. Check to ensure that
if nothing is blocking the ventilation holes or whether or not the
unit is being used at high altitudes.
c Press the
?
1
/
(ON/STANDBY) button to turn on the unit. If the
power is not turned on, disconnect the AC power cord, then
confirm the ON/STANDBY lamp is turned off. After about 10
seconds, reconnect the AC power cord and turn on the power
again. If the indicators still light up, the electrical system has a
problem. Consult with qualified Sony personnel.