7-2.Backlash calibration
Caution : "Gyro Gain Calibration" is not necessary
・ Connect the camera and PC through USB cable.
・ Turn the camera ON.
・ Place the camera in a regular position on a flat and steady board.
・ Start the SSIS calibration software.
・ Select "01.Backlash Calibration", and click "Exe".
・ After the adjustment is completed, the result will appear.
・ If the result is in the range of the above standard values, "Result" shows "OK", and the next "02. Shading
Central Calibration" will be selected.
・ The camera will be turned OFF automatically.
・ If "Result" shows "NG", make readjustment.
The cause of "NG" will be displayed in the below green frame.
Changed Page
 △× 1
Result of adjustment
- A31 ・ L100 -
△(Addition)
Backlash calibration standard value
X_CCW 0 - 8
X_CW 0 - 8
Y_CCW 0 - 8
Y_CW 0 - 8
INC
VMA43007-R.3780.A
March.6.2009