Device Fuse Replacement (Ni 784Xr/785Xr Only) - National Instruments NI 784xR User Manual

Ni r series intelligent daq
Hide thumbs Also See for NI 784xR:
Table of Contents

Advertisement

Caution
Never connect the +5 V power terminals to analog or digital ground or to any
other voltage source on the NI 78xxR device or any other device. Doing so can damage the
device and the computer. NI is not liable for damage resulting from such a connection.

Device Fuse Replacement (NI 784xR/785xR Only)

© National Instruments Corporation
(NI 784xR/785xR Devices)
user-replaceable socketed fuse to protect the supply from overcurrent
conditions. When an overcurrent condition occurs, check your cabling to
the +5 V terminals and replace the fuse as described in the Device Fuse
Replacement (NI 784xR/785xR Only) section.
The power rating on most devices is +4.75 to +5.25 VDC at 1 A.
Refer to the NI R Series Intelligent DAQ Specifications document, available
at
, to obtain the power rating for your device.
ni.com/manuals
NI 784xR/785xR devices have a replaceable fuse, Littelfuse part number
0453004 (NI part number 766247-01), that protects the device from
overcurrent through the power connector.
To replace a broken fuse in the NI 784xR/785xR, complete the following
steps:
1.
Power down and unplug the computer or PXI chassis.
2.
Remove the PCI device from the expansion slot on the computer, or
the PXI device from the PXI slot in the PXI chassis.
Chapter 2
All NI 784xR/785xR devices have a
2-29
Hardware Overview of the NI 78xxR
R Series Intelligent DAQ User Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ni 785xrNi 781xrNi 783xr784xrNi r series

Table of Contents