1.12.7 Removal of Fan Rotor and Fan Motor
Warning
Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Procedure:
Step
Remove the switch box.
Remove the bell mouth
(Two screws)
1 Removing the fan rotor
1
Remove the resin nut and
rotation stopper to
dismount the fan rotor.
2
Remove the resin nut
with spanner.
3
Pull down the fan rotor
slowly.
Part 5 – Disassembly and Maintenance
Procedure
Disassembly and Maintenance
A convex protrusion is
provided at the position of bell
mouth fixing screw to prevent
misjudgment with switch box
fixing position.
(S2653)
For removal of switch box,
refer to the "Removal of Switch
Box" on page 5-53.
Caution
When tighten or loosen the fan
rotor fixing resin nut,
hold the base of the fan.
see detail below.
Rotation
stopper
Resin nut
(S2655)
1
Points
3
(S2654)
5
5
5–55