6.2 CONNECTING C.O. LINES
6.2.1 Connecting Analog Loop Start Lines
Use a twisted pair (AWG #24 (or AWG #26) wire or cord to connect an analog loop start C.O.
line to pins 4 & 5 of the RJ45 jack on the 8TRK/8TRK2/16TRK or 4TRM installed in the
OfficeServ 7100 system.
Pin No.
1
Function
6.2.2 Connecting ISDN-PRI
Connect an ISDN-PRI C.O. circuit to the RJ-45 port on the OfficeServ TEPRI/TEPRIa card.
Using a standard, straight through eight conductor data cable or straight through eight
conductor line cord to connect the customer provided Channel Service Unit (CSU) to the
TEPRI/TEPRIa card as shown in
NOTES:
1. It may be necessary to cut off the CSU end of the cable and attach a different connector to
match that of the CSU. If possible, this connection should be soldered because good
connections are critical.
2. It is recommended that the CSU be connected to the network interface with a cable
supplied by the CSU manufacturer. If this is not possible or practical, a custom cable has to
be made up. This cable should be made from 22 gauge two pair cable with each pair
individually shielded. It is recommended that the connections on this cable be soldered
wherever possible to ensure good connections. The shielding of the cable should be
connected to ground at the CSU end only to prevent a ground loop.
3. T1/E1 is not supported on the OfficeServ 7100 system.
2
3
-
-
-
C.O. TIP
Figure 6.1 TIP and RING connections to Analog Trunk Cards