FAN MAINTENANCE - WITH GTMF REMOTE CONTROL

Note: To access the side and rear access panels both the gas and venting
will need to be disconnected(see vent/fl ue installation in this manual)
for proper removal.
There is no access to the blower from the front of this appliance.
Before you begin:
Shut off the gas supply to the unit.
Disconnect all electrical supply to the unit.
Always let the appliance cool to room temperature before servicing.
1. Remove 7 screws and loosen 4 screws along the bottom to remove fan
access panel -see Diagram 1a
Remove 4 screws to remove side access panel - see Diagram 1b
= Remove
= Loosen
2. Disconnect the fan wire harness through the rear panel. Disconnect 2 x
1/4" spade connectors to the fan terminals. Disconnect the ground lug to
the fan using the screw provided.
Strain Relief
Power Cord
Fan Controller
Wire Retainer
Fan Wire Harness
L390E-1 / HZI390E-1 Direct Vent Gas Insert
FOR L390EB OR HZI390EB
Diagram 1b
Diagram 1a
Fan Terminals
Ground Wire
Fan Mounting Bracket
Diagram 2
3. Remove fan and fan access panel from unit
4. Remove fan from back access panel by removing 3 screws from the
outside of fan access panel.
5. To install - reverse steps.
Electrical Grounding Instructions
This appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug.
Fan
MAINTENANCE
Diagram 3