Operation panel
4.1.3

Easy operation mode setting (easy setting mode)

Setting of Pr. 79 Operation mode selection according to combination of the start command and speed command can be
easily made.
Changing
Start command: external (STF/STR), frequency command: operate with
example
1.
Screen at power-ON
The monitor display appears.
2.
Easy operation mode setting
Press
and
3.
Operation mode selection
Turn
until
(refer to the table below for other settings)
4.
Operation mode setting
Press
to set.
REMARKS
is displayed ... Why?
Parameter write is disabled with "1" set in Pr. 77.
is displayed ... Why?
Setting cannot be made during operation. Turn the start switch (
 If
is pressed before pressing
display. If the easy setting mode is terminated while Pr.79 = "0 (initial setting)," the operation mode switches between the PU
operation mode and the External operation mode. Check the operation mode.
 Reset can be made with
 The priorities of the frequency commands when Pr. 79 = "3" are "Multi-speed operation (RL/RM/RH/REX) > PID control (X14) >
terminal 4 analog input (AU) > digital input from the operation panel".
60
Operation
for 0.5s.
appears.
Operation Panel Indication
Flickering
Flickering
Flickering
Flickering
Flickering
Flickering
Flickering
Flickering
.
Operation Method
Start command
External
(STF, STR)
External
(STF, STR)
Flicker ··· Parameter setting complete!!
The monitor display appears after 3s.
, the easy setting mode is terminated and the display goes back to the monitor
Display
Flickering
Flickering
Flickering
Frequency command
Analog
voltage input
Analog
voltage input
, STF or STR) OFF.