4.12.1 Speed display and speed setting (Pr. 37, Pr. 144, Pr. 505)

The monitor display and frequency setting of the PU (FR-PU04/FR-PU07) can be changed to the machine speed.
Parameter
Name
Number
37
Speed display
144
Speed setting switchover
505
Speed setting reference
The above parameter can be set when Pr. 160 Extended function display selection = "0". (Refer to page 197)

Performing IPM parameter initialization sets back the settings to the initial settings. (Refer to page 85)

Performing IPM parameter initialization changes the settings. (Refer to page 85)

The maximum value of the setting range differs according to the Pr. 1 Maximum frequency (Pr. 18 High speed maximum frequency), and it can be calculated from
the following formula.
Maximum setting value of Pr. 37
Note that the maximum setting value of Pr. 37 is 9998 if the result of the above formula exceeds 9998.

If Pr. 999 Automatic parameter setting setting is set to "20" or "21" while the machine speed is displayed (Pr.37  0), calculate the rotations per minute based on
the changed Pr.505 setting, and set Pr.37 again. (Refer to page 273)
 To display a machine speed, set Pr.37 to the machine speed at the frequency set in Pr. 505, and set Pr. 144 to the number of
motor poles (2, 4, 6, 8, 10).
For example, when Pr. 505 = "60Hz" and Pr. 37 = "1000", "1000" is displayed on the machine speed monitor at the running
frequency of 60Hz. When running frequency is 30Hz, "500" is displayed.
 When displaying the motor speed, set the number of motor poles + 100 (102, 104, 106, 108, 110) to Pr. 144.
 When both Pr. 37 and Pr. 144 have been set, their priorities are as given below.
Pr. 144, 102 to 110Pr. 37, 1 to 9998Pr. 144, 2 to 10
 A combination of the Pr.37 and Pr. 144 settings determines the monitored item and the setting increment as shown in the
table below. (Initial settings are outlined with bold borders)
Pr. 37
Pr. 144
Setting
Setting
0
2 to 10
(initial
102 to 110
value)
2 to 10
0.01
to 9998
102 to 110
Motor speed r/min conversion formula............ frequency  120/number of motor poles (Pr. 144)
*1
Machine speed conversion formula................... Pr. 37  frequency/Pr. 505 setting (Hz)
For Pr. 144 in the above formula, the value is "Pr. 144-100" when "102 to 110" is set in Pr. 144 and the value is "4" when Pr. 37 = 0 and Pr. 144 = 0.
Pr. 505 is always set as frequency (Hz).
150
Speed display and speed setting
Monitor display/PU main display
data selection
Cumulative monitor clear
Terminal FM function selection
Terminal FM standard setting
Terminal FM calibration
Initial
Setting Range
Value
0
0.01 to 9998
0, 2, 4, 6, 8, 10, 102,
4 
104, 106, 108, 110
60Hz

16777.215  60 (Hz)
<
Setting value of Pr. 1 (Pr. 18) (Hz)
Output Frequency
Monitor
0.01 Hz
1 r/min
*1
0.001 (Machine speed
)
0.001 (Machine speed
*1
0.01 Hz
Parameter that should be Set
Pr. 52, Pr. 54, Pr. 170, Pr. 171,
Pr. 268, Pr. 563, Pr. 564, Pr. 891
0
Frequency display, setting
Set the machine speed at Pr.505.
Set the number of motor poles when displaying the motor
speed.
1 to 120Hz
Set the reference speed for Pr. 37.
Set Frequency
Running Speed
Monitor
0.01 Hz
1 r/min
*1
)
0.001 (Machine speed
*1
0.01 Hz
Pr. 37, Pr. 144, Pr. 505
Pr. 54
Pr. 55, Pr. 56
Pr. 900
Description
Parameter Setting
Monitor
0.01 Hz
0.01 Hz
*1
1 r/min
1 r/min
*1
)
0.01 Hz
*1
0.01 Hz
0.01 Hz
Refer to
Page
150
152
152
157
158
*1