Parameter list
Func-
Parameter
Name
tion
255
Life alarm status display
256
Inrush current limit circuit life display
257
Control circuit capacitor life display
258
Main circuit capacitor life display
259
Main circuit capacitor life measuring
260
PWM frequency automatic switchover
261
Power failure stop selection
267
Terminal 4 input selection
268
Monitor decimal digits selection
269
Parameter for manufacturer setting. Do not set.
295
Magnitude of frequency change setting
296
Password lock level
297
Password lock/unlock
298
Frequency search gain
Rotation direction detection selection
299
at restarting
Communication operation command
338
source
Communication speed command
339
source
340
Communication startup mode selection
Communication EEPROM write
342
selection
343
Communication error count
374
Overspeed detection level
450
Second applied motor
495
Remote output selection
496
Remote output data 1
502
Stop mode selection at communication error
503
Maintenance timer
504
Maintenance timer alarm output set time
505
Speed setting reference
549
Protocol selection
PU mode operation command source
551
selection
552
Frequency jump range
553
PID deviation limit
554
PID signal operation selection
72
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
(0 to 15)
1
0
265
(0 to 100%)
1%
100%
265
(0 to 100%)
1%
100%
265
(0 to 100%)
1%
100%
265
0, 1 (2, 3, 8, 9)
1
0
265
0, 1
1
1
181
0 to 2
1
0
168
0 to 2
1
0
183
0, 1, 9999
1
9999
152
0, 0.01, 0.10, 1.00,
0.01
0
281
10.00
1 to 6, 101 to 106, 9999
1
9999
198
1000 to 9998 (0 to 5,
1
9999
198
9999)
0 to 32767, 9999
1
9999
161
0, 1, 9999
1
0
161
0, 1
1
0
214
0 to 2
1
0
214
0, 1, 10
1
0
213
0, 1
1
0
225
1
0
238
0 to 400Hz, 9999
0.01Hz
9999
173
0, 1, 9999
1
9999
123
0, 1, 10, 11
1
0
148
0 to 4095
1
0
148
222,
0 to 3
1
0
238
0 (1 to 9998)
1
0
268
0 to 9998, 9999
1
9999
268
1 to 120Hz
0.01Hz
60Hz
150
0, 1
1
0
238
2, 4, 9999
1
9999
214
0 to 30Hz, 9999
0.01Hz
9999
102
0 to 100%, 9999
0.1%
9999
250
0 to 3, 10 to 13
1
0
250
Customer
Parameter
Remarks
Setting
255
256
257
258
259
260
261
267
268
269
Parameter for manufacturer setting. Do not set.
295
296
297
298
299
338
339
340
342
343
374
450
495
496
502
503
504
505
549
551
552
553
554
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
GP
GP
GP
IPM
IPM
IPM
MFVC
MFVC
MFVC
3F
BF
2
40
C0
2
41
C1
2
42
C2
2
43
C3
2
44
C4
2
45
C5
2
4B
CB
2
4C
CC
2
67
E7
2
68
E8
2
69
E9
2
6A
EA
2
6B
EB
2
26
A6
3
27
A7
3
28
A8
3
2A
AA
3
2B
AB
3
4A
CA
3
32
B2
4
5F
DF
4
60
E0
4
02
82
5
03
83
5
04
84
5
05
85
5
31
B1
5
33
B3
5
34
B4
5
35
B5
5
36
B6
5