Daikin Altherma EDHQ011BB6V3 Installation Manual page 50

Unit for to water heat pump system
Hide thumbs Also See for Altherma EDHQ011BB6V3:
Table of Contents

Advertisement

First
Second
code
code
Setting name
F
Option setup
00
Pump operation stop
01
Space cooling permission temperature
02
Bottom plate heater ON temperature
03
Bottom plate heater hysteresis
04
Functionality of X14A
Underfloor heating screed dry-out program
05
Action number selection
06
Heating set point of selected action number [F-05]
07
Time of selected action number [F-05]
08
Underfloor heating screed dry-out program
enabled/disabled
09
Latest action number executed
(a) The storage and reheat function is only applicable in case [4-03]=4 or 5.
(b) Only possible to modify the first 3 minutes after power ON.
(c) For all action numbers of [F-05].
Installation manual
47
(b)
.
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
0
0/1
(enabled)
20
10~35
3
3~10
5
2~5
1
0/1
1
1~20
(c)
25.0
15~55
(c)
0
0~72
0 (OFF)
0/1
0~21
0
(Read only)
Unit for air to water heat pump system
Step
Unit
1
1
°C
1
°C
1
°C
1
1
°C
12
hour
1
0
E(D/B)(H/L)Q011~016BB
4PW67904-1 – 01.2011