Gas and Electric Supply Zones
36" (913 mm)
48" (1219 mm) 23⅛" (587 mm) 7" (178 mm)
NOTICE:
— If not already present, install gas shut-off valve in an
easily accessible location.
— Make sure all users know where and how to shut off
the gas supply to the range.
— Any opening in the wall behind the appliance and any
opening in the floor under the appliance must be
sealed.
The dual fuel ranges may be connected to the power
supply with a range supply cord kit or by hard-wiring to the
power supply. It is the responsibility of the installer to
provide the proper wiring components (cord or conduit and
wires) and complete the electrical connection as dictated
by local codes and ordinances, and/or the National Electric
Code. The units must be properly grounded. Refer to
"Step 7: Electrical Requirements, Connection & Grounding"
on page 16 for details.
The range must be connected only to the type of gas
for which it is certified. If the range is to be connected to
propane gas, ensure that the propane gas supply tank is
equipped with its own high pressure regulator in addition to
the pressure regulator supplied with the range (see
"Step 6: Gas Requirements and Hookup" on page 14).
English 8
36" or 48" (914 or 1219 mm)
GAS ZONE
10"
(254 mm)
A
Model
A
9⅛" (232 mm)
Range Width
ELECTRICAL
ZONE
3"
(76 mm)
B
C
B
7⅜" (187 mm) 7⅜" (187 mm) 9⅛" (232 mm)
7" (178 mm)
NOTE:
The range is designed for nearly-flush installation to the
back wall. For a successful installation, it may be
necessary to reposition the gas supply line and electrical
cord as the range is pushed back to its final position.
SUGGESTION: Carefully pull on a rope or twine looped
around the gas or electrical supply line as the range is
pushed back into its final installed position.

Electrical Supply

Installation of the range must be planned so that the rough-
in of the terminal block for the receptacle or conduit
connection will allow maximum clearance to the rear of the
unit.
2" (51 mm) max.
2" (51 mm) max.
2" (51 mm) max.
protrusion from wall
protrusion from wall
protrusion from wall
for gas or electrical
for gas or electrical
for gas or electrical
supply.
supply.
supply.
D
C
D
7⅞" (200 mm)
Figure 4: Gas & Electrical Supply Locations