Installation Clearances
{
36" or 42" (914 or 1067 mm) Wide Hood
For 36" Ranges
42" or 48" (1067 or 1219 mm) for Island
{
48" or 54" (1219 or 1372 mm) Wide Hood
For 48" Ranges
54" (1372 mm) for Island
30 30 30" (762 mm)
" (762 mm)
" (762 mm)
min.
min.
of overhea
overhea
overhead hood
hood
hood
Surface
Sur
36 36 36" (914 mm)
(914 mm)
(914 mm)
i
i
con on ontains combustible
combustible
combustible
materials
materials
materials
18" (457 mm)
minimum
*35⅞" (911 mm) Min. range height
with leveling legs fully retracted.
*36¾" (933 mm) Max. range height
with leveling legs fully extended.
*The range height is adjustable.
The level of the range top must
be at the same level or above
the counter top level.
CAUTION!
Do not install the range such that the oven door is flush
with the cabinet face. A flush installation could result in
damage to the cabinets due to exposure to high heat.
Min. Distance Between Overhead Cabinets
Min. Distance Between Overhead Cabinets
Min. Distance Between Overhead Cabinets
o
o
f f
f
36"
36"
48" Range – 48" (1219 mm)
48" Range – 48" (1219 mm)
48" Range – 48" (1219 mm)
f
f
rom
rom
bo bo bott tt ttom
om
om
t t
t
o
o
Cooking
Cooking
Cooking
f
f
hood
hood
36" or 48" (914 or 1219 mm)
36" or 48" (914 or 1219 mm)
For Gas Supply & Electrical Zones see Figure 4.
Zone sizes & positions differ according to model.
Shaded area above countertop
Shaded area above countertop
Shaded area above countertop
Shaded area above countertop
Shaded area above countertop
indicates minimum clearance
indicates minimum clearance
indicates minimum clearance
indicates minimum clearance
indicates minimum clearance
to combustible surfaces,
to combustible surfaces,
to combustible surfaces,
to combustible surfaces,
to combustible surfaces,
combustible materials
combustible materials
combustible materials
combustible materials
combustible materials
cannot be located within
cannot be located within
cannot be located within
cannot be located within
cannot be located within
this area.
this area.
this area.
this area.
this area.
Combustible
Combustible
Combustible
Material
Material
Material
Range
Range
36 36 36" (914 mm)
" (914 mm)
" (914 mm)
13" (330 mm)
13" (330 mm)
13" (330 mm)
max. Cabinet
max. Cabinet
max. Cabinet
depth
depth
depth
Range Width
Range Width
As defined in the "National Fuel Gas Code" (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1
scope and are not certified by CSA. Clearances of less than 12" (305 mm)
must be approved by the local codes and/or by the local authority having jurisdiction.
5" (127 mm)
5" (127 mm)
5" (127 mm)
min. to combustible
min. to combustible
min. to combustible
sidewall material
sidewall material
sidewall material
(both sides)
(both sides)
(both sides)
Figure 1: Cabinet Clearances
m CAUTION!
(See Fig. 2 & Fig. 3)
36" (914 mm) min.
to combustible
material
from Cooking
Surface
Cooking
Cooking
Cooking
Surface
Surface
Surface