Specifications - Lennox G71MPP SERIES Unit Information

Hide thumbs Also See for G71MPP SERIES:
Table of Contents

Advertisement

Gas
Heating
Performance
Maximum
Gas Manifold Pressure (in. w.g.)
Minimum
Gas Manifold Pressure (in. w.g.)
Connections
in.
Condensate Drain Trap (PVC pipe) − i.d.
with field supplied (PVC coupling) − o.d.
hose with hose clamp − i.d. x o.d.
Indoor
Wheel nominal diameter x width − in.
Blower
Shipping Data
Electrical characteristics
NOTE − Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non−weatherized furnaces.

SPECIFICATIONS

Model No.
Input − Btuh
Output − Btuh
Temperature rise range − _F
Natural Gas / LPG/Propane
Input − Btuh
Output − Btuh
Temperature rise range − _F
Natural Gas / LPG/Propane
1
AFUE
High static (CSA) − in. w.g.
Intake / Exhaust Pipe (PVC)
Gas pipe size IPS
Motor output − hp
Tons of add−on cooling
Air volume range − cfm
lbs. − 1 package
G71MPP
G71MPP
−36B−070
−36C−090
66,000
88,000
60,000
81,000
50 − 80
60 − 90
3.5 / 10.0
3.5 / 10.0
26,000
35,000
25,000
34,000
40 − 70
40 − 70
0.7 / 2.0
0.7 / 2.0
95.0%
95.0%
.80
.80
2 / 2
2 / 2
1/2
1/2
3/4
3/4
1 x 1−1/4
1 x 1 1/4
1/2
1/2
10 x 8
10 x 10
1/2
1/2
2 − 3.5
2 − 3.5
250 −1395
250 − 1395
149
160
120 volts − 60 hertz − 1 phase (less than 12 amps)
Page 2
G71MPP
G71MPP
−60C−090
−60C−110
88,000
110,000
81,000
103,000
50 − 80
50 − 80
3.5 / 10.0
3.5 / 10.0
35,000
44,000
34,000
42,000
40 − 70
40 − 70
0.7 / 2.0
0.7 / 2.0
95.0%
95.0%
.80
.80
2 / 2
2 / 2
1/2
1/2
3/4
3/4
1 x 1 1/4
1 x 1 1/4
1/2
1/2
11−1/2 x 10
11−1/2 x 10
1
1
3.5 − 5
3.5 − 5
450 − 2215
450 − 2210
171
184
G71MPP
−60D−135
132,000
123,000
55 − 85
3.5 / 10.0
53,000
51,000
40 − 70
0.7 / 2.0
95.0%
.80
3 / 3
1/2
3/4
1 x 1 1/4
1/2
11−1/2 x 10
1
3.5 − 5
450 − 2190
206

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents