G71Mpp−36B−070 Blower Performance (Less Filter); Blower Data - Lennox G71MPP SERIES Unit Information

Hide thumbs Also See for G71MPP SERIES:
Table of Contents

Advertisement

HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (–7.5% ) Heat CFM
Decrease (–15% ) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (–10%) Cool CFM
The effect of static pressure is included in air volumes shown.
Lennox Harmony IIIt Zone Control Applications − Minimum blower speed is 250 cfm.
The following control board configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Mode (Heating Blower Performance Table):
With a single−stage thermostat, furnace will operate at three, staged rates (40/70/100%) with a time delay between each stage (values in grey−shaded
columns).
With two−stage thermostat there are two modes available.
Traditional two−stage mode − W1 demand results in 70% firing rate. W2 results in 100% firing rate. No delay between stages. (values shown in 70%
and 100% grey−shaded columns only).
Variable Rate Capacity Mode − furnace automatically adjusts firing rate based on first− and second−stage cycle times. (all columns)
Cool Mode (Cooling Blower Performance table):
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second−stage COOL speed position
minimum 250 cfm.
G71MPP−36B−070 BLOWER MOTOR WATTS − COOLING
Blower Speed
Options
0
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80
Increase (+10%) Cool CFM
Low
55
70
Medium−Low
75
90
Medium−High
85
100
High
105
125
Default Cool CFM
Low
45
60
Medium−Low
60
75
Medium−High
65
85
High
85
100
Decrease (–10%) Cool CFM
Low
40
55
Medium−Low
45
60
Medium−High
50
65
High
60
75
G71MPP−36B−070 BLOWER PERFORMANCE (less filter)
0 through 0.80 in. w.g. External Static Pressure Range
40%
535
505
480
460
440
First Stage Cool Speed − cfm
Medium−
Medium
Low
Low
730
815
680
755
625
695
Motor Watts @ Various External Static Pressures − in. wg.
First Stage
90
110
130
145
160
110
130
150
170
190
120
145
165
185
205
150
170
190
210
235
80
95
115
130
145
95
110
130
145
165
105
125
140
155
175
120
140
160
180
200
70
85
100
120
130
80
95
115
135
145
85
105
125
145
160
95
115
135
150
170
TABLE 1
Heating Input Range and Blower Volume − CFM
50%
60%
70%
610
690
770
575
645
720
545
610
675
520
580
640
490
540
590
Blower Speed Selections
High
Low
High
(Default)
865
935
1015
795
855
930
730
775
830
0
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80
175
190
135
155
205
220
185
215
225
250
235
265
255
280
315
340
160
175
100
120
180
200
140
165
195
215
175
200
220
240
230
260
145
160
75
90
160
175
95
120
175
190
125
150
190
215
165
190
Page 4
80%
90%
870
975
810
905
760
845
715
790
655
715
Second Stage Cool Speed − cfm
Medium−
Medium
Low
High
1190
1280
1065
1155
950
1010
Second Stage
175
200
220
245
270
250
285
315
345
370
300
335
370
400
425
370
395
440
480
510
140
165
190
215
235
190
220
245
265
290
230
260
285
310
340
295
325
360
390
410
110
125
150
175
190
150
175
200
220
240
175
195
220
240
265
215
245
265
485
315
100%
1075
1000
930
870
780
High
(Default)
1395
1270
1105
295
320
395
420
455
480
540
570
255
275
315
340
365
390
435
455
210
225
260
285
290
320
340
370