G71Mpp−60D−135 Blower Performance - Side Return Air - Lennox G71MPP SERIES Unit Information

Hide thumbs Also See for G71MPP SERIES:
Table of Contents

Advertisement

G71MPP−60D−135 BLOWER PERFORMANCE (less filter) −− Side Return Air with Optional RAB Return Air Base
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (–7.5% ) Heat CFM
Decrease (–15% ) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (–10%) Cool CFM
The effect of static pressure is included in air volumes shown.
Lennox Harmony IIIt Zone Control Applications − Minimum blower speed is 450 cfm.
The following control board configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Mode (Heating Blower Performance Table):
With a single−stage thermostat, furnace will operate at three, staged rates (40/70/100%) with a time delay between each stage (values in grey−shaded
columns).
With two−stage thermostat there are two modes available.
Traditional two−stage mode − W1 demand results in 70% firing rate. W2 results in 100% firing rate. No delay between stages. (values shown in 70%
and 100% grey−shaded columns only).
Variable Rate Capacity Mode − furnace automatically adjusts firing rate based on first− and second−stage cycle times. (all columns)
Cool Mode (Cooling Blower Performance table):
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second−stage COOL speed position
minimum 450 cfm.
G71MPP−60D−135 BLOWER MOTOR WATTS − COOLING − Side Return Air with Optional RAB Return Air Base
Blower Speed
Options
0
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80
Increase (+10%) Cool CFM
Low
90
110
Medium−Low 105
130
Medium−High 145
170
High
200
230
Default Cool CFM
Low
70
90
Medium−Low
90
105
Medium−High
115
140
High
145
175
Decrease (–10%) Cool CFM
Low
60
75
Medium−Low
70
90
Medium−High
85
105
High
120
140
0 through 0.80 in. w.g. External Static Pressure Range
40%
1020
950
885
820
745
First Stage Cool Speed − cfm
Medium−
Medium
Low
Low
1080
1155
985
1055
875
945
Motor Watts @ Various External Static Pressures − in. wg.
First Stage
140
165
190
210
235
160
190
210
230
255
205
235
265
290
325
270
305
345
385
415
115
140
165
190
210
125
150
175
200
225
170
195
225
250
275
205
240
270
295
330
95
115
135
155
175
110
130
150
170
195
130
155
180
205
230
170
195
220
240
270
TABLE 11
Heating Input Range and Blower Volume − CFM
50%
60%
70%
1180
1340
1500
1095
1245
1395
1020
1160
1300
945
1075
1200
870
990
1110
Blower Speed Selections
High
Low
High
(Default)
1310
1480
1550
1190
1325
1400
1060
1190
1250
0
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80
260
285
235
265
285
310
290
325
355
390
420
460
445
480
580
630
230
250
170
200
250
270
200
230
300
325
330
365
365
395
435
480
195
215
135
155
215
235
160
185
250
270
220
255
295
325
330
365
Page 14
80%
90%
1650
1800
1535
1680
1435
1575
1335
1475
1230
1350
Second Stage Cool Speed − cfm
Medium−
Medium
Low
High
1660
1875
1510
1720
1345
1530
Second Stage
305
340
380
415
450
370
410
450
490
515
510
555
595
640
680
690
745
800
850
895
235
270
305
335
370
270
310
355
400
435
400
440
485
525
555
530
580
625
675
715
180
205
240
280
305
215
240
275
310
345
295
335
370
410
440
400
440
480
525
555
100%
1955
1825
1715
1610
1470
High
(Default)
2105
1920
1715
480
515
545
575
715
755
935
975
400
430
465
495
585
615
750
790
330
355
375
410
475
510
585
615