5.3.28 Tone Settings
RINGBACK_TONE_TIMING
Value Format
Description
Value Range
Default Value
Web User Interface Reference
HOLD_ALARM_FRQ
Value Format
Description
Value Range
Default Value
HOLD_ALARM_GAIN
Value Format
Description
Value Range
Default Value
CW_TONE1_FRQ
Value Format
Description
Value Range
Default Value
252
Administrator Guide
Comma-separated Integer
Specifies the pattern, in milliseconds, of ringback tones using up to 10
whole numbers (off 1, on 1, off 2, on 2...) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
0–16000 (0: Continuous)
Note
•
Avoid setting 1–50 for any of the values.
60,2000,3940
Tone Timings (Page 132)
Comma-separated Integer
Specifies the dual-tone frequencies, in hertz, of the hold alarm using 2
whole numbers separated by a comma.
0, 200–2000 (0: No tone)
425
INTEGER
Specifies the gain, in decibels, of the hold alarm.
-24–6 (dB)
0
Comma-separated Integer
Specifies the dual-tone frequencies, in hertz, of call waiting tone 1 using
2 whole numbers separated by a comma.
0, 200–2000 (0: No tone)
425
Document Version 2015-02