4.5.2 SIP Settings [Line 1]
Value Range
Default Value
Configuration File Reference

T1 Timer

Description
Value Range
Default Value
Configuration File Reference

T2 Timer

Description
Value Range
Default Value
Configuration File Reference

REGISTER Expires Timer

Description
Value Range
Default Value
Configuration File Reference
108
Administrator Guide
Max. 384 characters
Not stored.
SIP_URI_n (Page 203)
Specifies the default interval, in milliseconds, between transmissions of
SIP messages.
250
500
1000
2000
4000
500
SIP_TIMER_T1_n (Page 210)
Specifies the maximum interval, in seconds, between transmissions of
SIP messages.
2
4
8
16
32
4
SIP_TIMER_T2_n (Page 210)
Specifies the length of time, in seconds, that the registration remains
valid. This value is set in the "Expires" header of the REGISTER
request.
1–4294967295
3600
REG_EXPIRE_TIME_n (Page 208)