REG_INTERVAL_RATE_n
Parameter Name Example
Value Format
Description
Value Range
Default Value
REG_RTX_INTVL_n
Parameter Name Example
Value Format
Description
Value Range
Default Value
USE_DEL_REG_OPEN_n
Parameter Name Example
Value Format
Description
Value Range
Default Value
USE_DEL_REG_CLOSE_n
Parameter Name Example
Value Format
Description
Value Range
Default Value
Document Version 2015-02
REG_INTERVAL_RATE_1
INTEGER
Specifies the percentage of the "expires" value after which to refresh
registration by sending a new REGISTER message in the same dialog.
1–100
50
REG_RTX_INTVL_1
INTEGER
Specifies the interval, in seconds, between transmissions of the
REGISTER request when a registration results in failure (server no
reply or error reply).
1–86400
10
USE_DEL_REG_OPEN_1
BOOLEAN
Specifies whether to enable cancelation before registration when, for
example, the unit is turned on.
•
Y: Send un-REGISTER
•
N: Does not send
N
USE_DEL_REG_CLOSE_1
BOOLEAN
Specifies whether to enable the cancelation of registration before the
SIP function shuts down when, for example, the configuration has
changed.
•
Y: Send un-REGISTER
•
N: Does not send
N