4. REFRIGERANT FLOW DIAGRAM

Indoor Unit
SAP – K181AHA
Indoor Unit
SAP – K241AHA
Insulation of Refrigerant Tubing
IMPORTANT
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of
condensation, both tubes must be well insulated with a
proper insulation material. The thickness of the insulation
should be a min. 8 mm.
CAUTION
Indoor unit
Wide tube
O.D.
ø12.7 mm
(1/2 ")
Narrow tube
O.D.
ø6.35 mm
(1/4")
Indoor unit
Wide tube
O.D.
ø15.88 mm
(5/8 ")
Narrow tube
O.D.
ø6.35 mm
(1/4")
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the tube
to break or crack.
Outdoor Unit
Outdoor unit
Accumulator
Wide tube
service
valve
4-way
valve
Narrow
tube
service
valve
Outdoor Unit
Outdoor unit
Accumulator
Wide tube
service
valve
4-way
Muffler
valve
Narrow
tube
service
valve
12
SAP – C181AHA
Capillary for
liquid injection
Strainer
Cooling cycle
Heating cycle
SAP – C241AHA
Capillary for
liquid injection
Strainer
Cooling cycle
Heating cycle
Thickness:
Min. 8 mm
Wide tube
Insulation
Thickness:
Min. 8 mm
Narrow tube