Specifications; Unit Specifications; Specifications 2-1. Unit Specifications - Sanyo SAP–K181AHA–S Technical & Service Manual

Table of Contents

Advertisement

2. SPECIFICATIONS

2-1. Unit Specifications

Indoor Unit
SAP – K181AHA
Outdoor Unit
SAP – C181AHA
Power Source
Voltage rating
Capacity
Air circulation (High)
Moisture removal (High)
Available voltage range
Running amperes
Power input
Power factor
C.O.P.
Compressor locked rotor amperes
Controls / Temperature control
Control unit
Timer
Fan speeds
Airflow direction (Indoor)
Air filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant control
Operation sound
Refrigerant tubing connections
Max. allowable tubing length at shipment
Refrigerant tube
diameter
Refrigerant tube kit / Accessories
Unit dimensions
Package dimensions
Weight
Shipping volume
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating: Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
BTU/h
m
Liters/h
W/W
Indoor / Outdoor
Horizontal
Vertical
Indoor – Hi / Me / Lo
dB-A
Outdoor – Hi
dB-A
Narrow tube
mm (in.)
Wide tube
mm (in.)
Height
Width
Depth
Height
Width
Depth
Net
Shipping
240 V Single phase 50Hz
V
Cooling
kW
4.95
16,900
3
/h
760
2.7
V
A
10.6
W
2,360
%
93
2.10
A
Microprocessor / I.C. thermostat
Wireless remote control unit
1-hour OFF / 12-hour ON or OFF
3 and Auto / Auto (Hi, Lo)
g
41 / 38 / 36
53
m
Optional / Hanging wall bracket
Indoor Unit
mm
285
mm
995
mm
196
mm
276
mm
1,070
mm
363
kg
12.0
kg
15.0
3
m
0.11
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2
240
Heating
5.70
19,450
760
216 to 264
2,040
2.79
48
Manual
Auto
Washable, Anti-Mold
Rotary (Hermetic)
R22 / 1,330
Capillary tube
41 / 38 / 36
Flare type
7.5
6.35 (1/4)
12.7 (1/2)
Outdoor Unit
630
810
275
704
953
369
50.0
54.5
0.25
9.4
90
53

Hide quick links: