Table of Contents

Advertisement

Notice
CORRECTION
SERVICE FLASH
Please add this notice to the TECHNICAL & SERVICE MANUAL listed below.
Category :
SPLIT SYSTEM AIR CONDITIONER
SAP-K77GHAX + SAP-C77GHAX
SAP-K97GHAX + SAP-C97GHAX
Model :
SAP-K127GHAX + SAP-C127GHAX
Destination :
Russia + CIS + Africa
Serial No. :
Issue Number :
1
Indoor Model No.
SAP-K77GHAX
SAP-K97GHAX
SAP-K127GHAX
< Reference No. >
Current
SM700778
The reason for change
A : Correction
D : Design change
Page No.
of the Manual
56
PRODUCTION CHANGE
ADDED INFORMATION
Product Code No.
1 852 351 85
1 852 351 86
1 852 351 87
New
SM700778-01
B : Quality reliability
E : Addition of parts
9-2-2(2) Check "OPERATION" in the indoor unit has been added.
Outdoor Model No.
SAP-C77GHAX
SAP-C97GHAX
SAP-C127GHAX
C : Standardization
F : New information
Contents
FILE NO.
Date :
, 2009
Jul
Product Code No.
1 852 351 95
1 852 351 96
1 852 351 97
Reason
for change
F
SM
REFERENCE NO.
700778-01

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo SAP-K77GHAX

  • Page 1 Please add this notice to the TECHNICAL & SERVICE MANUAL listed below. Category : SPLIT SYSTEM AIR CONDITIONER Date : , 2009 SAP-K77GHAX + SAP-C77GHAX SAP-K97GHAX + SAP-C97GHAX Model : SAP-K127GHAX + SAP-C127GHAX Destination : Russia + CIS + Africa Serial No.
  • Page 2 SANYO Electric Co., Ltd. Jul. / 2009 R&D center...
  • Page 3 TECHNICAL & SERVICE MANUAL FILE NO. SAP-K77GHAX + SAP-C77GHAX SAP-K97GHAX + SAP-C97GHAX SAP-K127GHAX + SAP-C127GHAX Destination: Russia+CIS+Africa (50Hz) SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. Outdoor Model No. Product Code No. SAP-K77GHAX 1 852 351 85 SAP-C77GHAX...
  • Page 4 Important! When Transporting Please Read Before Starting Be careful when picking up and moving the indoor and This air conditioning system meets strict safety and outdoor units. Get a partner to help, and bend your knees operating standards. As the installer or service person, it when lifting to reduce strain on your back.
  • Page 5: Table Of Contents

    Table of Contents Page 1. OPERATING RANGE ........................2. SPECIFICATIONS 2-1. Unit Specifications ......................2-2. Major Component Specifications ..................2-3. Other Component Specifications ..................3. DIMENSIONAL DATA ........................4. REFRIGERANT FLOW DIAGRAM ....................4-1. Refrigerant Flow Diagram 5. PERFORMANCE DATA 5-1.
  • Page 6 Page 9. TROUBLESHOOTING 9-1. Check before and after troubleshooting ................9-2. Air conditioner does not operate.................... 9-3. Some part of air conditioner does not operate..............9-4. Air conditioner operates, but abnormalities are observed............. 10. CHECKING ELECTRICAL COMPONENTS 10-1.
  • Page 7: Operating Range

    1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 32 C D.B. / 23 C W.B. 43 C D.B. Cooling Minimum 19 C D.B. / 14 C W.B. 19 C D.B. Maximum 27 C D.B. 24 C D.B. / 18 C W.B. Heating Minimum 16 C D.B.
  • Page 8: Specifications

    2. SPECIFICATIONS 2-1. Unit Specifications Indoor Unit SAP-K77GHAX Outdoor Unit SAP-C77GHAX Power Source 220-240V Single phase 50Hz Voltage rating 220 / 230 / 240 V Performance Cooling Heating 2.10 2.10 2.20 2.20 2.20 Capacity 2.10 BTU/h 7,200 / 7,200 / 7,200...
  • Page 9 Indoor Unit SAP-K97GHAX Outdoor Unit SAP-C97GHAX Power Source 220-240V Single phase 50Hz Voltage rating 220 / 230 / 240 V Performance Cooling Heating Capacity 2.55 2.55 2.55 2.80 2.80 2.80 BTU/h 8,700 / 8,700 / 8,700 9,600 / 9,600 / 9,600 Air circulation (High) Moisture removal (High) Liters/h...
  • Page 10 Indoor Unit SAP-K127GHAX Outdoor Unit SAP-C127GHAX Power Source 220-240V Single phase 50Hz Voltage rating 220 / 230 / 240 V Performance Cooling Heating Capacity 3.55 3.55 3.55 3.70 3.70 3.70 BTU/h 12,100 / 12,100 / 12,100 12,600 / 12,600 / 12,600 Air circulation (High) Moisture removal (High) Liters/h...
  • Page 11: Major Component Specifications

    2-2. Major Component Specifications 2-2-1. Indoor Unit Indoor Unit SAP-K77GHAX Controller PCB Part No. CR-K77GHAX Controls Microprocessor Control circuit fuse 250V 3.15A Remote Control Unit RCS-7HS2E-G Controller PCB Part No. Cross-Flow Q'ty … Dia. and Length 1 … D100 / L637...
  • Page 12 Indoor Unit SAP-K97GHAX Controller PCB Part No. CR-K77GHAX Controls Microprocessor Control circuit fuse 250V 3.15A Remote Control Unit RCS-7HS2E-G Controller PCB Part No. Cross-Flow Q'ty … Dia. and Length 1 … D100 / L637 Fan Motor Type AC Motor Model … Q'ty IBH-884-066B …...
  • Page 13 Indoor Unit SAP-K127GHAX Controller PCB Part No. CR-K127GHAX Controls Microprocessor Control circuit fuse 250V 3.15A Remote Control Unit RCS-7HS2E-G Part No. Cross-Flow Q'ty … Dia. and Length 1 … D100 / L637 Fan Motor Type AC Motor Model … Q'ty IBH-884-066B …...
  • Page 14 2-2-2. Outdoor Unit Outdoor Unit SAP-C77GHAX Controller PCB Compressor Type Single Rotary Compressor model / Nominal output C-1R65H5S / 650W Compressor oil ... Amount SAY-56T … 350 Coil resistance (Ambient temp. 25 C) C - R : 4.68 C - S : 6.77 Safety devices Type External (OLR) Overload relay...
  • Page 15 Outdoor Unit SAP-C97GHAX Controller PCB Compressor Type Single Rotary Compressor model / Nominal output C-1R81H5T / 800W Compressor oil ... Amount SAY-56T …320 Coil resistance (Ambient temp. 25 C) C - R : 4.27 C - S : 4.56 Safety devices Type External ( OLR ) Overload relay MRA99248-9201...
  • Page 16 Outdoor Unit SAP-C127GHAX Controller PCB Compressor Type Single Rotary Compressor model / Nominal output C-R115H5A / 1,110W Compressor oil ... Amount SAY-56T … 520 Coil resistance (Ambient temp. 25 C) C - R : 1.962 C - S : 5.38 Safety devices Type External (OLR) Overload relay...
  • Page 17: Other Component Specifications

    2-3. Other Component Specifications Indoor Unit SAP-K77GHAX SAP-K97GHAX SAP-K127GHAX < Thermistor (Coil sensor) > Model PB2M-41E-S16-1 Resistance 15 kohm (at 0 C) 5.4 kohm (at 25 C) Outdoor Unit SAP-C77GHAX SAP-C97GHAX SAP-C127GHAX < Power Relay > Model EL200/240A1-F (M) Rating...
  • Page 18: Dimensional Data

    3. DIMENSIONAL DATA Indoor Unit SAP-K77GHAX SAP-K97GHAX SAP-K127GHAX...
  • Page 19 Outdoor Unit SAP-C77GHAX SAP-C97GHAX Wide tube service valve dia.9.52(3/8") Narrow tube service valve dia.6.35(1/4") Unit: mm...
  • Page 20 Outdoor Unit SAP-C127GHAX Wide tube service valve dia.12.7(1/2") Narrow tube service valve dia.6.35(1/4") Unit: mm...
  • Page 21: Refrigerant Flow Diagram

    4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram Indoor Unit SAP-K77GHAX Outdoor Unit SAP-C77GHAX SAP-K97GHAX SAP-C97GHAX Accumulator Wide tube service Wide tube valve 4-way valve O.D. 9.52 mm (3/8 ") Narrow tube Capillary tube service both for heating Narrow tube...
  • Page 22 Indoor Unit SAP-K127GHAX Outdoor Unit SAP-C127GHAX Accumulator Wide tube service Wide tube valve 4-way valve O.D. 12.7 mm (1/2 ") Narrow tube Capillary tube service (for heating) Narrow tube valve Cooling cycle Capillary tube O.D. both for heating Check 6.35 mm and cooling valve Heating cycle...
  • Page 23: Performance Data

    5. PERFORMANCE DATA 5-1. Performance charts Indoor Unit SAP-K77GHAX Outdoor Unit SAP-C77GHAX < Cooling Characteristics > < Heating Characteristics > (1) Operating current performance chart (1) Operating current performance chart Indoor inlet air Indoor inlet air D.B. temp. ( C) D.B.
  • Page 24 Indoor Unit SAP-K97GHAX Outdoor Unit SAP-C97GHAX < Cooling Characteristics > < Heating Characteristics > (1) Operating current performance chart (1) Operating current performance chart Indoor inlet air Indoor inlet air D.B. temp. ( C) D.B. temp. ( C) –5 Outdoor inlet air D.B. temp. ( C) Outdoor inlet air D.B.
  • Page 25 Indoor Unit SAP-K127GHAX Outdoor Unit SAP-C127GHAX < Cooling Characteristics > < Heating Characteristics > (1) Operating current performance chart (1) Operating current performance chart Indoor inlet air Indoor inlet air D.B. temp. ( C) D.B. temp. ( C) –5 Outdoor inlet air D.B. temp. ( C) Outdoor inlet air D.B.
  • Page 26: Air Throw Distance Charts

    5-2. Air Throw Distance Charts Indoor Unit SAP-K77GHAX Cooling Room air temp. : 27 C Fan speed High Horizontal distance (m) : F lap angle 0 , : Axis air velocity 0 : F lap angle 30 , : Axis air velocity 30 Heating Room air temp.
  • Page 27 Indoor Unit SAP-K97GHAX Cooling Room air temp. : 27 C Fan speed High Horizontal distance (m) : F lap angle 0 , : Axis air velocity 0 : F lap angle 30 , : Axis air velocity 30 Heating Room air temp. : 20 C Fan speed High...
  • Page 28 Indoor Unit SAP-K127GHAX Cooling Room air temp. : 27 C Fan speed High Horizontal distance (m) : Flap angle 0 , : Axis air velocity 0 : Flap angle 30 , : Axis air velocity 30 Heating Room air temp. : 20 C Fan speed High...
  • Page 29: Cooling Capacity

    5-3. Cooling Capacity Indoor Unit SAP-K77GHAX Outdoor Unit SAP-C77GHAX 230 V Single Phase 50 Hz RATING CAPACITY 2.10 kW AIR FLOW RATE 340 m EVAPORATOR CONDENSER ENT. TEMP. OUTDOOR AMBIENT TEMP. W.B. D.B. 2.12 2.02 1.93 1.84 1.73 1.59 0.53 0.58...
  • Page 30 Indoor Unit SAP-K97GHAX Outdoor Unit SAP-C97GHAX 230 V Single Phase 50 Hz RATING CAPACITY 2.55 kW AIR FLOW RATE 460 m EVAPORATOR CONDENSER ENT. TEMP. OUTDOOR AMBIENT TEMP. W.B. D.B. 2.57 2.46 2.35 2.23 2.10 1.93 0.67 0.73 0.78 0.83 0.91 0.99 1.80...
  • Page 31 Indoor Unit SAP-K127GHAX Outdoor Unit SAP-C127GHAX 230 V Single Phase 50 Hz RATING CAPACITY 3.55 kW AIR FLOW RATE 470 m EVAPORATOR CONDENSER ENT. TEMP. OUTDOOR AMBIENT TEMP. W.B. D.B. 3.58 3.42 3.27 3.11 2.92 2.69 0.90 0.97 1.04 1.12 1.26 1.41 2.34...
  • Page 32: Heating Capacity

    5-4. Heating Capacity –8 –5 Outdoor temperature ( C D.B.) NOTE … Point of Rating condition Black dot in the chart indicate the following rating condition. Indoor : 20 C D.B. Outdoor : 7 C D.B. / 6 C W.B. 2) Above characteristics indicate instantaneous operation, which does not take into account defrost operation.
  • Page 33: Electrical Data

    6. ELECTRICAL DATA 6-1. Electrical Characteristics Indoor Unit SAP-K77GHAX Outdoor Unit SAP-C77GHAX Cooling Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor Compressor Performance at 220/230/240V Single phase 50Hz Rating Conditions Running Amps. 0.17 0.21 3.02 Power Input 0.022 0.048...
  • Page 34 Indoor Unit SAP-K97GHAX Outdoor Unit SAP-C97GHAX Cooling Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor Compressor Performance at 220/230/240V Single phase 50Hz Rating Conditions Running Amps. 0.17 0.21 4.02 Power Input 0.028 0.048 0.884 0.960 Full Load Conditions Running Amps.
  • Page 35 Indoor Unit SAP-K127GHAX Outdoor Unit SAP-C127GHAX Cooling Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor Compressor Performance at 220/230/240V Single phase 50Hz Rating Conditions Running Amps. 0.19 0.39 5.62 Power Input 0.031 0.090 1.184 1.305 Full Load Conditions Running Amps.
  • Page 36: Electric Wiring Diagrams

    6-2. Electric Wiring Diagrams Indoor Unit SAP-K77GHAX SAP-K97GHAX SAP-K127GHAX To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing and/or cleaning any electrical parts.
  • Page 37 Outdoor Unit SAP-C77GHAX To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing and/or cleaning any electrical parts.
  • Page 38 Outdoor Unit SAP-C97GHAX To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing and/or cleaning any electrical parts.
  • Page 39 Outdoor Unit SAP-C127GHAX To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing and/or cleaning any electrical parts.
  • Page 40: Installation Instructions

    7. INSTALLATION INSTRUCTIONS 7-1. Installation Site Selection 7-1-1. Indoor Unit To prevent abnormal heat WARNING generation and the possibility of fire, do not place obstacles, 15 cm min. 5 cm enclosures and grilles in front 5 cm min. min. of or surrounding the air conditioner in a way that may block air flow.
  • Page 41 7-1-2. Outdoor Unit Exhaust fan AVOID: Hot air Heat source heat sources, exhaust fans, etc. (Fig. 4) damp, humid or uneven locations. Outdoor unit choose a place as cool as possible. choose a place that is well ventilated. Fig. 4 allow enough room around the unit for air intake/exhaust and possible maintenance.
  • Page 42: Recommended Wire Length And Diameter

    7-2. Recommended Wire Length and Diameter Regulations on wiring diameter differ from locality to locality. For field wiring requirements, please refer to your local electrical codes. Carefully observe these regulations when carrying out the installation. Supply cord and interconnection cord shall not be lighter than polychloroprene sheathed flexible cord (code designation 60245 IEC 57).
  • Page 43: Remote Control Unit Installation Position

    7-3. Remote Control Unit Installation Position The remote control unit can be operated from either a non-fixed position or a wall-mounted position. To ensure that the air conditioner operates correctly, do not install the remote control unit in the following places: In direct sunlight Behind a curtain or other place where it is covered More than 8 m away from the air conditioner...
  • Page 44: How To Test Run The Air Conditioner

    7-4. How to Test Run the Air Conditioner After turning on the power of the air conditioner, use the remote controller and follow the steps below to conduct the test run. (1) Set the remote controller in Test Run mode. (Fig. 8a) Press and hold the ECONOMY button and the 1HR.
  • Page 45: Removing And Installing The Grille

    7-5. Removing and Installing the Grille Basically, these models can be installed and wired without removing the grille. If access to any internal part is need- ed, follow the steps as given below. How to remove the grille Open the front panel until it is nearly horizontal, grasp the sections near the front panel arms on both sides, and then remove the panel by pushing the arms towards the outside while pulling the panel towards you.
  • Page 46: Functions

    8. FUNCTIONS 8-1. Room Temperature Control (1) Cooling Room temperature control is obtained by cycling the compressor ON and OFF under control of the room temperature sensor in the indoor unit. NOTE Some informations except for the room temperature are transmitted every 5 minutes by the remote control unit to the controller in the indoor unit.
  • Page 47 (2) Heating Room temperature control is obtained by cycling the compressor ON and OFF under control of the room temperature sensor in the remote control unit. The room temperature (and other information) is transmitted every 5 minutes by the remote control unit to the controller in the indoor unit.
  • Page 48: Dry Operation (Dehumidification)

    8-2. Dry Operation (Dehumidification) Dry operation uses the ability of the cooling cycle to remove moisture from the air, but by running at low level to dehumidify without greatly reducing the room temperature. The air conditioner repeats the cycle of turning ON and OFF automatically as shown in the chart below according to the room temperature.
  • Page 49: Automatic Switching Between Cooling And Heating

    8-3. Automatic Switching between Cooling and Heating When AUTO mode is selected, the microprocessor calculates the difference between the set temperature and the room temperature, and automatically switches to COOLING or HEATING mode to maintain the desired temperature. Room temp. Set temp.
  • Page 50: Freeze Prevention (Cooling And Dry)

    8-4. Freeze Prevention (Cooling and Dry) This function prevents freezing of the indoor heat exchange coil. When the temperature of the indoor heat exchange coil falls below 2 C for 2 minutes, the control circuit stops the outdoor fan and compressor (The compressor stops 3 seconds after the outdoor fan stopped). During this period, Indoor fan operates in LL.
  • Page 51: Automatic Fan Speed (Cooling And Dry)

    8-5. Automatic Fan Speed (Cooling and Dry) This automatically adjust the indoor fan speed by the difference between the room temperature and set temperature. < Cooling > Room temp. T+2 C T+1 C Set temp. Indoor fan H:High M:Medium L:Low...
  • Page 52: Cold Draft Prevention (Heating)

    8-6. Cold Draft Prevention (Heating) This function controls indoor fan speed so a strong draft of cold air will not blow out before the indoor heat exchange coil have sufficiently warmed up. Indoor fan speed varies according to the indoor heat exchange coil temperature as table shown below. Condition Indoor coil temperature ( C) Indoor fan speed...
  • Page 53: Overload Prevention (Heating)

    8-7. Overload Prevention (Heating) This function prevents overheating of the indoor heat exchange coil. When the temperature of the indoor heat exchange coil rises above T2 C, the outdoor fan stops, if the indoor fan is L (low speed), then the fan speed changes from L (low speed) to M (medium speed). When the temperature of the indoor heat exchange coil rises above T1 C, the compressor stops, and indoor fan runs in LL (very low speed).
  • Page 54: Automatic Fan Speed (Cooling, Dry And Heating)

    8-8. Automatic Fan Speed (Cooling, Dry and Heating) This automatically adjust the indoor fan speed by the difference between the room temperature and set temperature. < Cooling > Room temp. T+2 C T+1 C Set temp. Indoor fan H:High M:Medium L:Low <...
  • Page 55: Defrosting Operation (Heating)

    8-9. Defrosting Operation (Heating) Reverse-cycle Defrosting Defrosting Sequence Heating operation Compressor ON 4-way valve ON Frost detection Frosting is assumed mostly under the following condition. Indoor heat exchanger coil temperature drops 0.8 C per 6 minutes and it repeats 3 times in succession. Indoor heat exchanger coil temperature drops below certain extent.
  • Page 56: Troubleshooting

    9. TROUBLESHOOTING 9-1. Check before and after troubleshooting WARNING Hazardous voltage can cause ELECTRIC SHOCK or DEATH. Disconnect power or turn off circuit breaker before you start checking or servicing. 9-1-1. Check power supply wiring. Check that power supply wires are correctly connected to terminals L and N on the terminal plate in the outdoor unit.
  • Page 57: Air Conditioner Does Not Operate

    9-2. Air conditioner does not operate. 9-2-1. Circuit breaker trips (or fuse blows). (1) When the circuit breaker is set to ON, it is tripped soon. (Resetting is not possible.) < Failure Cause > There is a possibility of ground fault. There is a possibility of insulation fault.
  • Page 58 (2) Circuit breaker trips in several minutes after turning the air conditioner on. There is a possibility of short circuit. 1. Check capacity of circuit breaker. Replace with suitable one (larger capacity). 2. Is capacity of circuit breaker suitable ? In case of Heating operation : Measure resistance of outdoor fan Measure resistance of 4-way valve's...
  • Page 59 (3) Check remote control unit. 1. Try to run with another remote control unit. 2. Is the operation good ? First remote control unit is defective. In the case that the remote control transmission section is dirty, clean it. In the case that the remote control reception section in front of indoor unit is dirty, clean it.
  • Page 60 9-2-3. Only outdoor unit does not run. (1) Check setting temperature. COOL Is room temperature too low ? 1. Try to lower setting temperature by temperature setting button ( button). 2. Does outdoor unit run ? Check to see if inter-unit wiring is correctly connected between indoor and outdoor unit.
  • Page 61: Some Part Of Air Conditioner Does Not Operate

    9-3. Some part of air conditioner does not operate. 9-3-1. Only indoor fan does not run. Check fan casing Remove foreign foreign matter on matter or repair. inside. If you turn fan gently once or twice by hand, can the fan turn ? Fan motor winding burnout or foreign Repair or replace.
  • Page 62 9-3-4. Only compressor does not run. Is overload relay (OLR) Check compressor motor working ? capacitor. Is temperature of compressor Measure resistance of abnormally high ? compressor motor winding. Does refrigerant gas shortage ? Charge refrigerant gas (R22). Measure Power supply Rotor may be locked up.
  • Page 63: Air Conditioner Operates, But Abnormalities Are Observed

    9-4. Air conditioner operates, but abnormalities are observed. 9-4-1. Poor cooling. Is remote control unit placed where Change position of remote it can detect room temperature control unit. properly ? Are wide and narrow tubes between Insulate both wide and narrow indoor unit and outdoor unit tubes separately and then insulated ?
  • Page 64: Checking Electrical Components

    10. CHECKING ELECTRICAL COMPONENTS 10-1. Measurement of Insulation Ground wire Resistance Clip The insulation is in good condition if the resistance exceeds 2M ohm. Probe 10-1-1. Power Supply Cord Insulation Clamp the grounding wire of power cord with the lead tester clip of the insulation resistance tester and measure the Fig.
  • Page 65: Checking Continuity Of Fuse On Pcb Ass'y

    10-2. Checking Continuity of Fuse Fuse on PCB Ass'y Remove the PCB Ass'y from the electrical component box. Then pull out the fuse from the PCB Ass'y. (Fig. 5) Check for continuity using a multimeter as shown in PCB Ass'y Fig.
  • Page 66: Maintenance

    11. MAINTENANCE 11-1. Address Setting of the Remote Control Unit The address can be set in order to prevent interfer- Jumper wire for address switching ence between remote controllers when 2 indoor units are installed near each other. To set a different address, it is necessary to change the address on the second remote controller.
  • Page 67: Appendix Instruction Manual

    APPENDIX INSTRUCTION MANUAL SAP-K77GHAX + SAP-C77GHAX SAP-K97GHAX + SAP-C97GHAX SAP-K127GHAX + SAP-C127GHAX...
  • Page 68 Features This air conditioner is equipped with cooling, heating, and drying functions. Details on these functions are provided below; refer to these descriptions when using the air conditioner. • Microprocessor Controlled Operation • Automatic Switching between Cooling and The interior compartment of the remote control Heating unit contains several features to facilitate This unit automatically switches between cooling...
  • Page 69: Product Information

    Product Information Electrical Requirements If you have problems or questions concerning your 1. All wiring must conform to the local electrical codes. Air Conditioner, you will need the following information. Consult your dealer or a qualified electrician for details. Model and serial numbers are on the nameplate 2.
  • Page 70: Names Of Parts

    Names of Parts Unit Display and Operation Button Air intakes INDOOR UNIT INDOOR UNIT REMOTE CONTROL receiver OPERATION lamp OPERATION TIMER TIMER lamp Air outlet OPERATION Remote control ON/OFF button unit (ON/OFF) Drain hose IMPORTANT Refrigerant tubes Avoid using radio equipment such as mobile phone near (within 1 m) the remote control receiver.
  • Page 71 Remote Control Unit (Display) Displayed when transmitting data Displayed when indoor unit sensor is in use Displayed when setting timer Symbols (1) Operation mode (4) Timer AUTO ........12-hour ON Timer....HEAT ........12-hour OFF Timer....MILD DRY ......1-hour OFF Timer.
  • Page 72 Remote Control Unit Transmitter Display 1 HR.Timer button ON/OFF operation button (1-Hour off timer) Temperature setting buttons (TEMP.) MODE selector button FLAP button ECONOMY button FAN SPEED selector button CANCEL button ON TIME / OFF TIME setting buttons ACL button (ALL CLEAR) Transmitter When you press the buttons on the remote control unit, the...
  • Page 73 Remote Control Unit (continued) ON TIME/OFF TIME setting No display: The timer does not operate. buttons : The air conditioner starts at the set time. : The air conditioner stops at the set time. FAN SPEED selector button : The air conditioner automatically decides the fan speeds. : High fan speed : Medium fan speed : Low fan speed...
  • Page 74: Using The Remote Control Unit

    Remote Control Unit Installation Position Using the Remote The remote control unit may be operated either from Control Unit a non-fixed position or from a wall-mounted position. To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following How to Install Batteries places: DO NOT...
  • Page 75: Operation With The Remote Control Unit

    Operation with the Check that the circuit breaker on the power NOTE Remote Control Unit panel is turned on and that the operation selector of the indoor unit is in the ON position. If the automatic operation settings of the unit 1.
  • Page 76: Adjusting The Fan Speed

    Operation with the Remote A. In Cooling and DRY Mode: ( Control Unit (continued) When the ECONOMY mode is selected, the air conditioner automatically raises the temperature setting 1 °C when 30 minutes have passed after 3. Adjusting the Fan Speed the selection was made, and then another 1 °C after another 30 minutes have passed, regardless of A.
  • Page 77: Special Remarks

    Special Remarks Using the 12-Hour ON and OFF Timer ‘‘DRY’’ ( ) Operation How it works? 1. TIMER ON mode (Example) • Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically.
  • Page 78: Using The 1-Hour Off Timer

    2. TIMER OFF mode (Example) • The display changes immediately to its status previous to timer setting, but the indication remains. • Press the TIMER ON button or the TIMER OFF button to display the time remaining on the timer in seconds. •...
  • Page 79: Tips For Energy Saving

    Adjusting the Airflow 2. Combining the 1-Hour OFF Timer and 12-Hour ON Timer Direction By combining the 1-Hour OFF Timer and 12-Hour ON Timer, it is possible to have the unit operate for just 1. Horizontal one hour from the present time, and then have it The horizontal airflow can be adjusted by moving the switch on again later at a time specified by you.
  • Page 80: Operation Without The Remote Control Unit

    Care and Cleaning NOTE • The flap automatically closes when the unit is off. • During the heating operation, the fan speed will be very low and the flap will be in the horizontal position (position ) until the air being blown out of the unit begins to warm.
  • Page 81 Care and Cleaning Cleaning the main unit and remote control unit (continued) • Wipe clean using a soft, dry cloth. • To remove stubborn dirt, moisten a cloth in warm water Cleaning no hotter than 40 °C, wring thoroughly, and then wipe. Use a vacuum cleaner to remove light dust.
  • Page 82: Troubleshooting

    Troubleshooting Operating Range If your air conditioner does not work properly, first check The air conditioner is operable within the temperature the following points before requesting service. ranges as listed below: If it still does not work properly, contact your dealer or service center.
  • Page 83 SANYO Electric Co., Ltd. Jul. / 2009 R&D center...
  • Page 84 TECHNICAL & SERVICE MANUAL FILE NO. SAP-K77GHAX + SAP-C77GHAX SAP-K97GHAX + SAP-C97GHAX SAP-K127GHAX + SAP-C127GHAX Destination: Russia+CIS+Africa (50Hz) SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. Outdoor Model No. Product Code No. SAP-K77GHAX 1 852 351 85 SAP-C77GHAX...
  • Page 85 Important! When Transporting Please Read Before Starting Be careful when picking up and moving the indoor and This air conditioning system meets strict safety and outdoor units. Get a partner to help, and bend your knees operating standards. As the installer or service person, it when lifting to reduce strain on your back.
  • Page 86 Table of Contents Page 1. OPERATING RANGE ........................2. SPECIFICATIONS 2-1. Unit Specifications ........................................2-2. Major Component Specifications 2-3. Other Component Specifications ..................3. DIMENSIONAL DATA ........................4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram ....................5. PERFORMANCE DATA 5-1.
  • Page 87 Page 9. TROUBLESHOOTING 9-1. Check before and after troubleshooting ................9-2. Air conditioner does not operate.................... 9-3. Some part of air conditioner does not operate..............9-4. Air conditioner operates, but abnormalities are observed............. 10. CHECKING ELECTRICAL COMPONENTS 10-1.
  • Page 88: Operating Range

    1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 32 C D.B. / 23 C W.B. 43 C D.B. Cooling Minimum 19 C D.B. / 14 C W.B. 19 C D.B. Maximum 27 C D.B. 24 C D.B. / 18 C W.B. Heating Minimum 16 C D.B.
  • Page 89: Specifications

    2. SPECIFICATIONS 2-1. Unit Specifications Indoor Unit SAP-K77GHAX Outdoor Unit SAP-C77GHAX Power Source 220-240V Single phase 50Hz Voltage rating 220 / 230 / 240 V Performance Cooling Heating Capacity 2.10 2.10 2.10 2.20 2.20 2.20 BTU/h 7,200 / 7,200 / 7,200...
  • Page 90 Indoor Unit SAP-K97GHAX Outdoor Unit SAP-C97GHAX Power Source 220-240V Single phase 50Hz Voltage rating 220 / 230 / 240 V Performance Cooling Heating Capacity 2.55 2.55 2.55 2.80 2.80 2.80 BTU/h 8,700 / 8,700 / 8,700 9,600 / 9,600 / 9,600 Air circulation (High) Moisture removal (High) Liters/h...
  • Page 91 Indoor Unit SAP-K127GHAX Outdoor Unit SAP-C127GHAX Power Source 220-240V Single phase 50Hz Voltage rating 220 / 230 / 240 V Performance Cooling Heating Capacity 3.55 3.55 3.55 3.70 3.70 3.70 BTU/h 12,100 / 12,100 / 12,100 12,600 / 12,600 / 12,600 Air circulation (High) Moisture removal (High) Liters/h...
  • Page 98: Other Component Specifications

    2-3. Other Component Specifications Indoor Unit SAP-K77GHAX SAP-K97GHAX SAP-K127GHAX < Thermistor (Coil sensor) > Model PB2M-41E-S16-1 Resistance 15 kohm (at 0 C) 5.4 kohm (at 25 C) Outdoor Unit SAP-C77GHAX SAP-C97GHAX SAP-C127GHAX < Power Relay > Model EL200/240A1-F (M) Rating...
  • Page 99: Dimensional Data

    3. DIMENSIONAL DATA Indoor Unit SAP-K77GHAX SAP-K97GHAX SAP-K127GHAX...
  • Page 100 Outdoor Unit SAP-C77GHAX SAP-C97GHAX Wide tube service valve dia.9.52(3/8") Narrow tube service valve dia.6.35(1/4") Unit: mm...
  • Page 101 Outdoor Unit SAP-C127GHAX Wide tube service valve dia.12.7(1/2") Narrow tube service valve dia.6.35(1/4") Unit: mm...
  • Page 102: Refrigerant Flow Diagram

    4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram Indoor Unit SAP-K77GHAX Outdoor Unit SAP-C77GHAX SAP-K97GHAX SAP-C97GHAX Accumulator Wide tube service Wide tube valve 4-way valve O.D. 9.52 mm (3/8 ") Narrow tube Capillary tube service both for heating Narrow tube...
  • Page 103 Indoor Unit SAP-K127GHAX Outdoor Unit SAP-C127GHAX Accumulator Wide tube service Wide tube valve 4-way valve O.D. 12.7 mm (1/2 ") Narrow tube Capillary tube service (for heating) Narrow tube valve Cooling cycle Capillary tube O.D. both for heating Check 6.35 mm and cooling valve Heating cycle...
  • Page 104: Performance Data

    5. PERFORMANCE DATA 5-1. Performance charts Indoor Unit SAP-K77GHAX Outdoor Unit SAP-C77GHAX < Cooling Characteristics > < Heating Characteristics > (1) Operating current performance chart (1) Operating current performance chart Indoor inlet air Indoor inlet air D.B. temp. ( C) D.B.
  • Page 105 Indoor Unit SAP-K97GHAX Outdoor Unit SAP-C97GHAX < Cooling Characteristics > < Heating Characteristics > (1) Operating current performance chart (1) Operating current performance chart Indoor inlet air Indoor inlet air D.B. temp. ( C) D.B. temp. ( C) –5 Outdoor inlet air D.B. temp. ( C) Outdoor inlet air D.B.
  • Page 106 Indoor Unit SAP-K127GHAX Outdoor Unit SAP-C127GHAX < Cooling Characteristics > < Heating Characteristics > (1) Operating current performance chart (1) Operating current performance chart Indoor inlet air Indoor inlet air D.B. temp. ( C) D.B. temp. ( C) –5 Outdoor inlet air D.B. temp. ( C) Outdoor inlet air D.B.
  • Page 107: Air Throw Distance Charts

    5-2. Air Throw Distance Charts Indoor Unit SAP-K77GHAX Cooling Room air temp. : 27 C Fan speed High Horizontal distance (m) : F lap angle 0 , : Axis air velocity 0 : F lap angle 30 , : Axis air velocity 30 Heating Room air temp.
  • Page 108 Indoor Unit SAP-K97GHAX Cooling Room air temp. : 27 C Fan speed High Horizontal distance (m) : F lap angle 0 , : Axis air velocity 0 : F lap angle 30 , : Axis air velocity 30 Heating Room air temp. : 20 C Fan speed High...
  • Page 109 Indoor Unit SAP-K127GHAX Cooling Room air temp. : 27 C Fan speed High Horizontal distance (m) : Flap angle 0 , : Axis air velocity 0 : Flap angle 30 , : Axis air velocity 30 Heating Room air temp. : 20 C Fan speed High...
  • Page 110: Cooling Capacity

    5-3. Cooling Capacity Indoor Unit SAP-K77GHAX Outdoor Unit SAP-C77GHAX 230 V Single Phase 50 Hz RATING CAPACITY 2.10 kW AIR FLOW RATE 340 m EVAPORATOR CONDENSER ENT. TEMP. OUTDOOR AMBIENT TEMP. W.B. D.B. 2.12 2.02 1.93 1.84 1.73 1.59 0.53 0.58...
  • Page 111 Indoor Unit SAP-K97GHAX Outdoor Unit SAP-C97GHAX 230 V Single Phase 50 Hz RATING CAPACITY 2.55 kW AIR FLOW RATE 460 m EVAPORATOR CONDENSER ENT. TEMP. OUTDOOR AMBIENT TEMP. W.B. D.B. 2.57 2.46 2.35 2.23 2.10 1.93 0.67 0.73 0.78 0.83 0.91 0.99 1.80...
  • Page 112 Indoor Unit SAP-K127GHAX Outdoor Unit SAP-C127GHAX 230 V Single Phase 50 Hz RATING CAPACITY 3.55 kW AIR FLOW RATE 470 m EVAPORATOR CONDENSER ENT. TEMP. OUTDOOR AMBIENT TEMP. W.B. D.B. 3.58 3.42 3.27 3.11 2.92 2.69 0.90 0.97 1.04 1.12 1.26 1.41 2.34...
  • Page 114: Electrical Data

    6. ELECTRICAL DATA 6-1. Electrical Characteristics Indoor Unit SAP-K77GHAX Outdoor Unit SAP-C77GHAX Cooling Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor Compressor Performance at 220/230/240V Single phase 50Hz Rating Conditions Running Amps. 0.17 0.21 3.02 Power Input 0.022 0.048...
  • Page 115 Indoor Unit SAP-K97GHAX Outdoor Unit SAP-C97GHAX Cooling Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor Compressor Performance at 220/230/240V Single phase 50Hz Rating Conditions Running Amps. 0.17 0.21 4.02 Power Input 0.028 0.048 0.884 0.960 Full Load Conditions Running Amps.
  • Page 116 Indoor Unit SAP-K127GHAX Outdoor Unit SAP-C127GHAX Cooling Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor Compressor Performance at 220/230/240V Single phase 50Hz Rating Conditions Running Amps. 0.19 0.39 5.62 Power Input 0.031 0.090 1.184 1.305 Full Load Conditions Running Amps.
  • Page 117: Electric Wiring Diagrams

    6-2. Electric Wiring Diagrams Indoor Unit SAP-K77GHAX SAP-K97GHAX SAP-K127GHAX To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing and/or cleaning any electrical parts.
  • Page 118 Outdoor Unit SAP-C77GHAX To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing and/or cleaning any electrical parts.
  • Page 119 Outdoor Unit SAP-C97GHAX To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing and/or cleaning any electrical parts.
  • Page 120 Outdoor Unit SAP-C127GHAX To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing and/or cleaning any electrical parts.
  • Page 121: Installation Instructions

    7. INSTALLATION INSTRUCTIONS 7-1. Installation Site Selection 7-1-1. Indoor Unit To prevent abnormal heat WARNING generation and the possibility of fire, do not place obstacles, 15 cm min. 5 cm enclosures and grilles in front 5 cm min. min. of or surrounding the air conditioner in a way that may block air flow.
  • Page 122 7-1-2. Outdoor Unit Exhaust fan AVOID: Hot air Heat source heat sources, exhaust fans, etc. (Fig. 4) damp, humid or uneven locations. Outdoor unit choose a place as cool as possible. choose a place that is well ventilated. Fig. 4 allow enough room around the unit for air intake/exhaust and possible maintenance.
  • Page 126: Removing And Installing The Grille

    7-5. Removing and Installing the Grille Basically, these models can be installed and wired without removing the grille. If access to any internal part is need- ed, follow the steps as given below. How to remove the grille Open the front panel until it is nearly horizontal, grasp the sections near the front panel arms on both sides, and then remove the panel by pushing the arms towards the outside while pulling the panel towards you.
  • Page 127: Functions

    8. FUNCTIONS 8-1. Room Temperature Control (1) Cooling Room temperature control is obtained by cycling the compressor ON and OFF under control of the room temperature sensor in the indoor unit. Some informations except for the room temperature are transmitted every 5 minutes NOTE by the remote control unit to the controller in the indoor unit.
  • Page 128 (2) Heating Room temperature control is obtained by cycling the compressor ON and OFF under control of the room temperature sensor in the remote control unit. The room temperature (and other information) is transmitted every 5 minutes by the remote control unit to the controller in the indoor unit.
  • Page 129: Dry Operation (Dehumidification)

    8-2. Dry Operation (Dehumidification) Dry operation uses the ability of the cooling cycle to remove moisture from the air, but by running at low level to dehumidify without greatly reducing the room temperature. The air conditioner repeats the cycle of turning ON and OFF automatically as shown in the chart below according to the room temperature.
  • Page 130: Automatic Switching Between Cooling And Heating

    8-3. Automatic Switching between Cooling and Heating When AUTO mode is selected, the microprocessor calculates the difference between the set temperature and the room temperature, and automatically switches to COOLING or HEATING mode to maintain the desired temperature. Room temp. Set temp.
  • Page 131: Freeze Prevention (Cooling And Dry)

    8-4. Freeze Prevention (Cooling and Dry) This function prevents freezing of the indoor heat exchange coil. When the temperature of the indoor heat exchange coil falls below 2 C for 2 minutes, the control circuit stops the outdoor fan and compressor (The compressor stops 3 seconds after the outdoor fan stopped). During this period, Indoor fan operates in LL.
  • Page 132: Automatic Fan Speed (Cooling And Dry)

    8-5. Automatic Fan Speed (Cooling and Dry) This automatically adjust the indoor fan speed by the difference between the room temperature and set temperature. < Cooling > Room temp. T+2 C T+1 C Set temp. Indoor fan H:High M:Medium L:Low...
  • Page 133: Cold Draft Prevention (Heating)

    8-6. Cold Draft Prevention (Heating) This function controls indoor fan speed so a strong draft of cold air will not blow out before the indoor heat exchange coil have sufficiently warmed up. Indoor fan speed varies according to the indoor heat exchange coil temperature as table shown below. Condition Indoor coil temperature ( C) Indoor fan speed...
  • Page 134: Overload Prevention (Heating)

    8-7. Overload Prevention (Heating) This function prevents overheating of the indoor heat exchange coil. When the temperature of the indoor heat exchange coil rises above T2 C, the outdoor fan stops, if the indoor fan is L (low speed), then the fan speed changes from L (low speed) to M (medium speed). When the temperature of the indoor heat exchange coil rises above T1 C, the compressor stops, and indoor fan runs in LL (very low speed).
  • Page 135: Automatic Fan Speed (Cooling, Dry And Heating)

    8-8. Automatic Fan Speed (Cooling, Dry and Heating) This automatically adjust the indoor fan speed by the difference between the room temperature and set temperature. < Cooling > Room temp. T+2 C T+1 C Set temp. Indoor fan H:High M:Medium L:Low <...
  • Page 138: Air Conditioner Does Not Operate

    9-2. Air conditioner does not operate. 9-2-1. Circuit breaker trips (or fuse blows). (1) When the circuit breaker is set to ON, it is tripped soon. (Resetting is not possible.) < Failure Cause > There is a possibility of ground fault. There is a possibility of insulation fault.
  • Page 139 (2) Circuit breaker trips in several minutes after turning the air conditioner on. There is a possibility of short circuit. 1. Check capacity of circuit breaker. Replace with suitable one (larger capacity). 2. Is capacity of circuit breaker suitable ? In case of Heating operation : Measure resistance of outdoor fan Measure resistance of 4-way valve's...
  • Page 140 (2) Check remote control unit. 1. Try to run with another remote control unit. 2. Is the operation good ? First remote control unit is defective. In the case that the remote control transmission section is dirty, clean it. In the case that the remote control reception section in front of indoor unit is dirty, clean it.
  • Page 141 9-2-3. Only outdoor unit does not run. (1) Check setting temperature. COOL Is room temperature too low ? 1. Try to lower setting temperature by temperature setting button ( button). 2. Does outdoor unit run ? Check to see if inter-unit wiring is correctly connected between indoor and outdoor unit.
  • Page 142: Some Part Of Air Conditioner Does Not Operate

    9-3. Some part of air conditioner does not operate. 9-3-1. Only indoor fan does not run. Check fan casing Remove foreign foreign matter on matter or repair. inside. If you turn fan gently once or twice by hand, can the fan turn ? Fan motor winding burnout or foreign Repair or replace.
  • Page 143 9-3-4. Only compressor does not run. Is overload relay (OLR) Check compressor motor working ? capacitor. Is temperature of compressor Measure resistance of abnormally high ? compressor motor winding. Does refrigerant gas shortage ? Charge refrigerant gas (R22). Measure Power supply Rotor may be locked up.
  • Page 144: Air Conditioner Operates, But Abnormalities Are Observed

    9-4. Air conditioner operates, but abnormalities are observed. 9-4-1. Poor cooling. Is remote control unit placed where Change position of remote it can detect room temperature control unit. properly ? Are wide and narrow tubes between Insulate both wide and narrow indoor unit and outdoor unit tubes separately and then insulated ?
  • Page 145: Checking Electrical Components

    10. CHECKING ELECTRICAL COMPONENTS 10-1. Measurement of Insulation Ground wire Resistance Clip The insulation is in good condition if the resistance exceeds 2M ohm. Probe 10-1-1. Power Supply Cord Insulation Clamp the grounding wire of power cord with the lead tester clip of the insulation resistance tester and measure the Fig.
  • Page 147: Maintenance

    11. MAINTENANCE 11-1. Address Setting of the Remote Control Unit The address can be set in order to prevent interfer- Jumper wire for address switching ence between remote controllers when 2 indoor units are installed near each other. To set a different address, it is necessary to change the address on the second remote controller.
  • Page 148: Appendix Instruction Manual

    APPENDIX INSTRUCTION MANUAL SAP-K77GHAX + SAP-C77GHAX SAP-K97GHAX + SAP-C97GHAX SAP-K127GHAX + SAP-C127GHAX...
  • Page 164 SANYO Electric co., Ltd. Nov. / 2008 R&D center...

Table of Contents