7. REFRIGERANT FLOW DIAGRAM

Indoor unit KHS1232
Indoor Unit
Insulation of Refrigerant Tubing
IMPORTANT
To prevent heat loss and wet floors due to dripping of
condensation, both the wide and narrow tubes
must be well insulated with a proper insulation
material. The thickness of the insulation should be a
min. 5/16 in.
After a tube has been insu-
CAUTION
lated, never try to bend it
into a narrow curve
because it can cause the
tube to break or crack.
Outdoor unit CH1232
Wide tube
service
Wide tube
valve
Muffler
O.D.
1/2"
(12.7 mm)
Narrow
tube
service
Narrow tube
valve
Strainer
O.D.
1/4"
(6.35 mm)
Outdoor Unit
Accumulator
4-way
valve
Capillary tube
Capillary tube
Drier
Check
valve
Thickness:
Min. 5/16"
Wide tube
12
Check
port
Cooling cycle
Heating cycle
Insulation
Thickness:
Min. 5/16"
Narrow tube