Service And Repairs; Battery Storage; Battery Care - Toro Groundsmaster 4100-D Service Manual

Hide thumbs Also See for Groundsmaster 4100-D:
Table of Contents

Advertisement

Service and Repairs

NOTE: For engine component repair information (e.g.
starter motor), see the Kubota Workshop Manual, Die-
sel Engine, 03--M--E3B Series at the end of Chapter 3
-- Kubota Diesel Engine.

Battery Storage

If the machine will be stored for more than 30 days:
1. Remove the battery and charge it fully (see Battery
Service in this section).
2. Either store battery on a shelf or on the machine.
3. Leave cables disconnected if the battery is stored on
the machine.

Battery Care

1. Battery electrolyte level must be properly main-
tained. The top of the battery must be kept clean. lf the
machine is stored in a location where temperatures are
extremely high, the battery will discharge more rapidly
than if the machine is stored in a location where temper-
atures are cool.
WARNING
Wear safety goggles and rubber gloves when
working with electrolyte. Charge battery in a
well ventilated place so gasses produced
while charging can dissipate. Since the gases
are explosive, keep open flames and electrical
sparks away from the battery; do not smoke.
Nausea may result if the gases are inhaled. Un-
plug charger from electrical outlet before con-
necting or disconnecting charger leads to or
from battery posts.
IMPORTANT: Do not remove fill caps while clean-
ing.
2. Check battery condition weekly or after every 50
hours of operation. Keep terminals and entire battery
case clean because a dirty battery will discharge slowly.
A. Clean battery by washing entire case with a solu-
tion of baking soda and water. Rinse with clear water.
B. Coat battery posts and cable connectors with ter-
minal protector (Toro Part No. 107--0392) or petro-
leum jelly to prevent corrosion.
Electrical System
4. Store battery in a cool atmosphere to avoid quick de-
terioration of the battery charge.
5. To help prevent the battery from freezing, make sure
it is fully charged (see Battery Service in this section).
3. Battery cables must be tight on terminals to provide
good electrical contact.
Connecting cables to the wrong post could re-
sult in personal injury and/or damage to the elec-
trical system.
4. If corrosion occurs at terminals, disconnect cables.
Always disconnect negative (--) cable first. Clean
clamps and terminals separately. Connect cables with
positive (+) cable first. Coat battery posts and cable con-
nectors with terminal protector (Toro Part No.
107--0392) or petroleum jelly to prevent corrosion.
5. Check electrolyte level every 25 operating hours and
every 30 days if machine is in storage.
6. Maintain cell level with distilled water. Do not fill cells
above the fill line.
Page 5 - - 44
WARNING
Groundsmaster 4100--D/4110--D

Advertisement

Table of Contents
loading

This manual is also suitable for:

30449Groundsmaster 4110-d30447

Table of Contents