3. Slide air duct hose onto heater/evaporator assembly
covers and secure with cable tie.
4. Remove caps that were placed on hoses and fittings
during the removal process. Using labels placed during
removal, properly secure hoses to heater core, evapo-
rator and drier--receiver.
5. Make sure that condensation hoses are secured to
bottom housing of heater/evaporator assembly and are
routed to cab frame for proper draining of condensate.
6. Connect wire harness connectors to fan motor and
binary switch on drier--receiver.
Operator Cab
7. Make sure that all machine air conditioning compo-
nents are installed and secure.
8. Have a certified air conditioning service technician
evacuate the air conditioning system completely, prop-
erly recharge the system with R134a refrigerant and
then leak test the system. A/C system capacity is
approximately 1 pound 6 ounces (624 gm) of R134a re-
frigerant.
9. Operate the heater system to make sure that no en-
gine coolant leaks exist.
10.Lower and secure roof assembly (see Roof Assem-
bly Installation in this section).