STEP 2: CABINET PREPARATION
GAS AND ELECTRIC SUPPLY ZONES:
FIG. 3a Gas & Electrical Supply Zone for PRSG304 & PRSG36 All-Gas Ranges
Typical placement shown.
Other placement of Gas
Supply and Electrical
Receptacle within the
Electrical and Gas Supply
Zone is acceptable.
NOTE:
A Manual Gas
Shut-Off Valve
(not shown) must
be easily accessible
through an adjacent
cabinet without
moving the range.
FIG. 3b Gas & Electrical Supply Zone for PRSE304 Dual-Fuel Ranges
Typical placement shown.
Other placement of Gas Supply
and Electrical Receptacle within
the Electrical and Gas Supply
Zone is acceptable.
NOTE:
A Manual Gas
Shut-Off Valve
(not shown)
must be easily
accessible
through an
adjacent cabinet
Protrusion from Wall
without moving
the range.
FIG. 3c Gas & Electrical Supply Zone for PRSE36 and PRSE48 Dual-Fuel Ranges
Typical placement shown.
Other placement of Gas Supply
and Electrical Receptacle within
the Electrical and Gas Supply
Zone is acceptable.
NOTE:
A Manual Gas
Shut-Off Valve
(not shown)
must be easily
accessible
through an
adjacent cabinet
without moving
Protrusion from Wall
the range.
Model
A
PRSE36
7"
PRSE48
12"
Three-Prong,
120 VAC
Receptacle
1 3/4" Maximum
Protrusion from Wall
for Gas Supply
5/8" Flex Line to
Appliance
1/2"
N.P.T.
2" Maximum
for Gas Supply
5/8" Flex Line to
Appliance
Gas
Supply
1/2"
Zone
N.P.T.
2" Maximum
for Gas Supply
B
9"
*
Ground Wire
16"
5/8" Flex Line to
Appliance
Gas & Electrical
Supply Zone
1/2" N.P.T.
5"
240 VAC Receptacle
(Shown) or Junction
Box
Gas &
Electrical
Supply Zone
4-3/4"
240 VAC Receptacle
(Shown) or Junction
Box
Electrical
Supply
Zone
3-1/4"
3-1/2"
Page 6
The All-Gas Ranges are factory
equipped with a power supply cord
with a three-prong grounding plug.
IT MUST BE PLUGGED INTO A MATING,
GROUNDING-TYPE, 120VAC RECEP-
TACLE THAT IS CONNECTED TO A
CORRECTLY POLARIZED AND GROUND-
ED 120VAC CIRCUIT. (See STEP 6.)
The range must be connected only to
the type of gas for which it is certified.
If the range is to be connected to
propane gas, ensure that the propane
gas supply tank is equipped with its own
high pressure regulator in addition to the
pressure regulator supplied with the
range. (See STEP 5.)
The Dual-Fuel ranges may be connected
to the power supply with a 3-pole, 3-
conductor range supply cord kit, a 3-
pole, 4-conductor range supply cord kit
or by hard-wiring to the power supply. It is
the responsibility of the installer to provide
the proper wiring components (cord or
conduit and wires) and complete the
electrical connection as dictated by
local codes and ordinances, and/or the
National Electric Code. The units must be
properly grounded. Refer to Step 6 for
details.
The range must be connected only to the
type of gas for which it is certified. If the
range is to be connected to propane
gas, ensure that the propane gas supply
tank is equipped with its own high pressure
regulator in addition to the pressure
regulator supplied with the range. (See
STEP 5.)
The Dual-Fuel ranges may be connected
to the power supply with a 3-pole, 3-
conductor range supply cord kit, a 3-
pole, 4-conductor range supply cord kit
or by hard-wiring to the power supply. It is
the responsibility of the installer to provide
the proper wiring components (cord or
conduit and wires) and complete the
electrical connection as dictated by
local codes and ordinances, and/or the
National Electric Code. The units must be
properly grounded. Refer to Step 6 for
details.
The range must be connected only to the
type of gas for which it is certified. If the
range is to be connected to propane
gas, ensure that the propane gas supply
tank is equipped with its own high pressure
regulator in addition to the pressure re-
gulator supplied with the range. (See STEP 5.)