Thermador PRSG304 Installation Instructions Manual page 12

Table of Contents

Advertisement

STEP 4: INSTALLING ANTI-TIP DEVICE
PRSG304 and PRSG36 All-Gas Ranges (Figures 9, 10, 12A, 12B, and 13)
STEP A:
Determine the best location for the
PRSG Mounting Bracket. The bracket may be
mounted to the wall or floor behind the range,
off-set from either the left or right side wall by
2-3/4" for Model PRSG304 or 4-5/8" for Model
PRSG36.
-
Locate the bracket on the side of the
range that will not interfere with the gas
supply line, electrical wiring, conduit, or
any other item.
-
Select either the rear wall or the floor
for mounting the bracket, based upon
which will provide the greatest holding
strength.
STEP B:
Set the bracket on the floor and turn it
until it is oriented properly. The bracket
should be standing up on end. The set of
mounting flanges having one (1) hole per side
should be resting on the floor, and the other set
of mounting flanges having two (2) holes per
side should be positioned vertically facing the
rear.
STEP C:
Slide the bracket left or right to the
correct position for the model that you are
installing. The distance from the side wall to
the center line of the closest mounting hole is
2-3/4" for Model PRSG304 and 4-5/8" for
Model PRSG36.
STEP D:
If you plan to mount the bracket to the
rear wall, slide the bracket back until it is
positioned against the rear wall. If you plan to
mount the bracket to the floor, position the
bracket such that the center line of the mount-
ing holes in the horizontal bracket flanges are
7/16" in front of the rear edge of the range side
panel when the range is in its final installed
position.
STEP E:
With the bracket properly positioned,
use the bracket as a template and mark the
location of the selected mounting holes in
either the rear wall (4 holes) or the floor (2
holes) with a pencil.
STEP F:
Drill holes at the marked locations.
STEP G:
Using the screws provided, securely
fasten the bracket to the rear wall (4 screws) or
floor (2 screws).
FIG. 12A. PRSG Wall Mount (0" Clearance)
PLAN VIEW
May Be used On Either
Left or Right (Right Shown)
SIDE VIEW
FIG. 12B PRSG Wall Mount (Max 2" Clearance)
PLAN VIEW
May Be used On Either
Left or Right (Right Shown)
SIDE VIEW
Page 12
PRSG304: 2-3/4"
PRSG36: 4-5/8"
PRSG304: 2-3/4"
PRSG36: 4-5/8"
Maxi-
mum Up
"
to 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prsg36Prse304Prse36Prse48

Table of Contents