Thermador PRSG304 Installation Instructions Manual page 11

Table of Contents

Advertisement

Parts Required for Installation of Anti-Tip Device:
PRSG304 and PRSG36 All-Gas Ranges (Figures 9 and 10)
Thermador Part No.
Qty.
15-10-916
4
15-10-771
1
15-10-772
1
15-10-909
1
15-10-910
1
15-10-911
2
15-10-948
2
FIG. 10. Adjustable Anti-Tip Channel PRSG304 and PRSG36
All-Gas Ranges
This Hole For Flush
Mount of PRSG304
1-9/32"
PRSE304 and PRSE36 Dual-Fuel Ranges
(Figure 11)
Thermador Part No.
Qty.
15-10-916
4
15-10-770
1
IMPORTANT INSTALLATION INFORMATION:
The anti-tip bracket may be attached to a solid
wood cabinet having a minimum wall thickness
of 3/4".
The thickness of the wall or floor may require use
of longer screws available at your local hardware
store.
In all cases, at least two (2) of the bracket
mounting screws must be fastened to solid wood
or metal.
Use appropriate anchors when fastening the
mounting bracket to any material other than
hardwood or metal.
Prepare holes at fastener locations as identified
below:
-
For walls, wall studs, or floors composed of
solid wood or metal, drill 1/8" pilot holes.
STEP 4: INSTALLING ANTI-TIP DEVICE
Description
Screw, Phillips, #10 x 1-1/2"
Anti-Tip Channel, Adjustable,
PRSG
Mounting Bracket, PRSG
Bolt, Hex Head, 1/4-20 x
1/2"
Nut, Hex, 1/4-20
Washer, Flat, 1/4-20
Screw, Phillips, #10 x 1/2",
Type B
5-1/2"
This Hole For Flush
Mount of PRSG36
1-17/32"
Description
Screw, Phillips, #10 x
1-1/2 "
Anti-Tip Channel/
Mounting Bracket
Page 11
FIG. 9. Mounting Kit for PRSG304 and
PRSG36 All Gas Ranges
15-10-772 (1 Each)
15-10-909 (1 Each))
15-10-948 (2 Each)
FIG. 11. Mounting Kit for PRSE304 and
PRSE36 Dual-Fuel Ranges
15-10-770 (1 Each )
-
For walls or floors composed of drywall,
sheet-rock, or other soft materials, drill 3/
16" holes to a minimum depth of 1-3/4", then
tap plastic anchors into each of the holes
using a hammer.
-
For walls or floors composed of concrete or
concrete block, drill 3/16" holes to a mini-
mum depth of 1-3/4", then tap concrete
anchors into each of the holes using a
hammer.
-
For walls or floors having ceramic tile cover-
ings, drill 3/16" holes through the tile only,
then drill into the material behind the tile as
indicated immediately above.
If the range is moved to a new location, the Anti-
Tip Device must be removed and reinstalled.
15-10-916 (4 Each)
15-10-771 (1 Each)
15-10-911 (2 Each)
15-10-910 (1 Each)
15-10-916 (4 Each)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prsg36Prse304Prse36Prse48

Table of Contents